{"id":50580,"date":"2026-04-02T08:12:44","date_gmt":"2026-04-02T08:12:44","guid":{"rendered":"https:\/\/www.kdmsteel.com\/?p=50580"},"modified":"2026-04-03T16:34:07","modified_gmt":"2026-04-03T16:34:07","slug":"wall-mounted-vs-floor-mounted-distribution-boxes","status":"publish","type":"post","link":"https:\/\/www.kdmsteel.com\/pt\/wall-mounted-vs-floor-mounted-distribution-boxes\/","title":{"rendered":"Wall-Mounted vs Floor-Mounted Distribution Boxes"},"content":{"rendered":"<p>Choosing between wall-mounted vs floor-mounted distribution boxes can have a big effect on the safety, economy, and bottom line of your project. This guide helps you compare both choices based on installation needs, space limitations, and long-term operating requirements so you can make smart buying decisions.<\/p>\n<div id=\"ez-toc-container\" class=\"ez-toc-v2_0_82_2 counter-hierarchy ez-toc-counter ez-toc-grey ez-toc-container-direction\">\n<div class=\"ez-toc-title-container\">\n<p class=\"ez-toc-title\" style=\"cursor:inherit\">\u00cdndice<\/p>\n<span class=\"ez-toc-title-toggle\"><a href=\"#\" class=\"ez-toc-pull-right ez-toc-btn ez-toc-btn-xs ez-toc-btn-default ez-toc-toggle\" aria-label=\"Alternar \u00edndice\"><span class=\"ez-toc-js-icon-con\"><span class=\"\"><span class=\"eztoc-hide\" style=\"display:none;\">Alternar<\/span><span class=\"ez-toc-icon-toggle-span\"><svg style=\"fill: #999;color:#999\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\" class=\"list-377408\" width=\"20px\" height=\"20px\" viewbox=\"0 0 24 24\" fill=\"none\"><path d=\"M6 6H4v2h2V6zm14 0H8v2h12V6zM4 11h2v2H4v-2zm16 0H8v2h12v-2zM4 16h2v2H4v-2zm16 0H8v2h12v-2z\" fill=\"currentColor\"><\/path><\/svg><svg style=\"fill: #999;color:#999\" class=\"arrow-unsorted-368013\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\" width=\"10px\" height=\"10px\" viewbox=\"0 0 24 24\" version=\"1.2\" baseprofile=\"tiny\"><path d=\"M18.2 9.3l-6.2-6.3-6.2 6.3c-.2.2-.3.4-.3.7s.1.5.3.7c.2.2.4.3.7.3h11c.3 0 .5-.1.7-.3.2-.2.3-.5.3-.7s-.1-.5-.3-.7zM5.8 14.7l6.2 6.3 6.2-6.3c.2-.2.3-.5.3-.7s-.1-.5-.3-.7c-.2-.2-.4-.3-.7-.3h-11c-.3 0-.5.1-.7.3-.2.2-.3.5-.3.7s.1.5.3.7z\"\/><\/svg><\/span><\/span><\/span><\/a><\/span><\/div>\n<nav><ul class='ez-toc-list ez-toc-list-level-1' ><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-1\" href=\"https:\/\/www.kdmsteel.com\/pt\/wall-mounted-vs-floor-mounted-distribution-boxes\/#What_Is_a_Wall-Mounted_Distribution_Box\" >What Is a Wall-Mounted Distribution Box?<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-2\" href=\"https:\/\/www.kdmsteel.com\/pt\/wall-mounted-vs-floor-mounted-distribution-boxes\/#What_Is_a_Floor-Mounted_Distribution_Box\" >What Is a Floor-Mounted Distribution Box?<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-3\" href=\"https:\/\/www.kdmsteel.com\/pt\/wall-mounted-vs-floor-mounted-distribution-boxes\/#Side-by-Side_Comparison_between_Wall-Mounted_vs_Floor-Mounted_Distribution_Boxes\" >Side-by-Side Comparison between Wall-Mounted vs Floor-Mounted Distribution Boxes<\/a><ul class='ez-toc-list-level-3' ><li class='ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-4\" href=\"https:\/\/www.kdmsteel.com\/pt\/wall-mounted-vs-floor-mounted-distribution-boxes\/#Mounting_Method_Physical_Support\" >Mounting Method &amp; Physical Support<\/a><ul class='ez-toc-list-level-4' ><li class='ez-toc-heading-level-4'><a class=\"ez-toc-link ez-toc-heading-5\" href=\"https:\/\/www.kdmsteel.com\/pt\/wall-mounted-vs-floor-mounted-distribution-boxes\/#Wall-Mounted_Distribution_Box\" >Wall-Mounted Distribution Box<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-4'><a class=\"ez-toc-link ez-toc-heading-6\" href=\"https:\/\/www.kdmsteel.com\/pt\/wall-mounted-vs-floor-mounted-distribution-boxes\/#Floor-Mounted_Distribution_Box\" >Floor-Mounted Distribution Box<\/a><\/li><\/ul><\/li><li class='ez-toc-page-1 ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-7\" href=\"https:\/\/www.kdmsteel.com\/pt\/wall-mounted-vs-floor-mounted-distribution-boxes\/#Space_Utilization\" >Space Utilization<\/a><ul class='ez-toc-list-level-4' ><li class='ez-toc-heading-level-4'><a class=\"ez-toc-link ez-toc-heading-8\" href=\"https:\/\/www.kdmsteel.com\/pt\/wall-mounted-vs-floor-mounted-distribution-boxes\/#Wall-Mounted_Distribution_Box-2\" >Wall-Mounted Distribution Box<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-4'><a class=\"ez-toc-link ez-toc-heading-9\" href=\"https:\/\/www.kdmsteel.com\/pt\/wall-mounted-vs-floor-mounted-distribution-boxes\/#Floor-Mounted_Distribution_Box-2\" >Floor-Mounted Distribution Box<\/a><\/li><\/ul><\/li><li class='ez-toc-page-1 ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-10\" href=\"https:\/\/www.kdmsteel.com\/pt\/wall-mounted-vs-floor-mounted-distribution-boxes\/#Capacity_Internal_Volume\" >Capacity &amp; Internal Volume<\/a><ul class='ez-toc-list-level-4' ><li class='ez-toc-heading-level-4'><a class=\"ez-toc-link ez-toc-heading-11\" href=\"https:\/\/www.kdmsteel.com\/pt\/wall-mounted-vs-floor-mounted-distribution-boxes\/#Wall-Mounted_Distribution_Box-3\" >Wall-Mounted Distribution Box<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-4'><a class=\"ez-toc-link ez-toc-heading-12\" href=\"https:\/\/www.kdmsteel.com\/pt\/wall-mounted-vs-floor-mounted-distribution-boxes\/#Floor-Mounted_Distribution_Box-3\" >Floor-Mounted Distribution Box<\/a><\/li><\/ul><\/li><li class='ez-toc-page-1 ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-13\" href=\"https:\/\/www.kdmsteel.com\/pt\/wall-mounted-vs-floor-mounted-distribution-boxes\/#Load-Bearing_Equipment_Weight\" >Load-Bearing &amp; Equipment Weight<\/a><ul class='ez-toc-list-level-4' ><li class='ez-toc-heading-level-4'><a class=\"ez-toc-link ez-toc-heading-14\" href=\"https:\/\/www.kdmsteel.com\/pt\/wall-mounted-vs-floor-mounted-distribution-boxes\/#Wall-Mounted_Distribution_Box-4\" >Wall-Mounted Distribution Box<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-4'><a class=\"ez-toc-link ez-toc-heading-15\" href=\"https:\/\/www.kdmsteel.com\/pt\/wall-mounted-vs-floor-mounted-distribution-boxes\/#Floor-Mounted_Distribution_Box-4\" >Floor-Mounted Distribution Box<\/a><\/li><\/ul><\/li><li class='ez-toc-page-1 ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-16\" href=\"https:\/\/www.kdmsteel.com\/pt\/wall-mounted-vs-floor-mounted-distribution-boxes\/#Accessibility_Maintenance\" >Accessibility &amp; Maintenance<\/a><ul class='ez-toc-list-level-4' ><li class='ez-toc-heading-level-4'><a class=\"ez-toc-link ez-toc-heading-17\" href=\"https:\/\/www.kdmsteel.com\/pt\/wall-mounted-vs-floor-mounted-distribution-boxes\/#Wall-Mounted_Distribution_Box-5\" >Wall-Mounted Distribution Box<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-4'><a class=\"ez-toc-link ez-toc-heading-18\" href=\"https:\/\/www.kdmsteel.com\/pt\/wall-mounted-vs-floor-mounted-distribution-boxes\/#Floor-Mounted_Distribution_Box-5\" >Floor-Mounted Distribution Box<\/a><\/li><\/ul><\/li><li class='ez-toc-page-1 ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-19\" href=\"https:\/\/www.kdmsteel.com\/pt\/wall-mounted-vs-floor-mounted-distribution-boxes\/#Application_Complexity\" >Application Complexity<\/a><ul class='ez-toc-list-level-4' ><li class='ez-toc-heading-level-4'><a class=\"ez-toc-link ez-toc-heading-20\" href=\"https:\/\/www.kdmsteel.com\/pt\/wall-mounted-vs-floor-mounted-distribution-boxes\/#Wall-Mounted_Distribution_Box-6\" >Wall-Mounted Distribution Box<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-4'><a class=\"ez-toc-link ez-toc-heading-21\" href=\"https:\/\/www.kdmsteel.com\/pt\/wall-mounted-vs-floor-mounted-distribution-boxes\/#Floor-Mounted_Distribution_Box-6\" >Floor-Mounted Distribution Box<\/a><\/li><\/ul><\/li><li class='ez-toc-page-1 ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-22\" href=\"https:\/\/www.kdmsteel.com\/pt\/wall-mounted-vs-floor-mounted-distribution-boxes\/#Aesthetic_Integration\" >Aesthetic Integration<\/a><ul class='ez-toc-list-level-4' ><li class='ez-toc-heading-level-4'><a class=\"ez-toc-link ez-toc-heading-23\" href=\"https:\/\/www.kdmsteel.com\/pt\/wall-mounted-vs-floor-mounted-distribution-boxes\/#Wall-Mounted_Distribution_Box-7\" >Wall-Mounted Distribution Box<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-4'><a class=\"ez-toc-link ez-toc-heading-24\" href=\"https:\/\/www.kdmsteel.com\/pt\/wall-mounted-vs-floor-mounted-distribution-boxes\/#Floor-Mounted_Distribution_Box-7\" >Floor-Mounted Distribution Box<\/a><\/li><\/ul><\/li><li class='ez-toc-page-1 ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-25\" href=\"https:\/\/www.kdmsteel.com\/pt\/wall-mounted-vs-floor-mounted-distribution-boxes\/#Structural_Installation_Requirements\" >Structural &amp; Installation Requirements<\/a><ul class='ez-toc-list-level-4' ><li class='ez-toc-heading-level-4'><a class=\"ez-toc-link ez-toc-heading-26\" href=\"https:\/\/www.kdmsteel.com\/pt\/wall-mounted-vs-floor-mounted-distribution-boxes\/#Wall-Mounted_Distribution_Box-8\" >Wall-Mounted Distribution Box<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-4'><a class=\"ez-toc-link ez-toc-heading-27\" href=\"https:\/\/www.kdmsteel.com\/pt\/wall-mounted-vs-floor-mounted-distribution-boxes\/#Floor-Mounted_Distribution_Box-8\" >Floor-Mounted Distribution Box<\/a><\/li><\/ul><\/li><li class='ez-toc-page-1 ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-28\" href=\"https:\/\/www.kdmsteel.com\/pt\/wall-mounted-vs-floor-mounted-distribution-boxes\/#Cost_Complexity\" >Cost &amp; Complexity<\/a><ul class='ez-toc-list-level-4' ><li class='ez-toc-heading-level-4'><a class=\"ez-toc-link ez-toc-heading-29\" href=\"https:\/\/www.kdmsteel.com\/pt\/wall-mounted-vs-floor-mounted-distribution-boxes\/#Wall-Mounted_Distribution_Box-9\" >Wall-Mounted Distribution Box\u00a0<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-4'><a class=\"ez-toc-link ez-toc-heading-30\" href=\"https:\/\/www.kdmsteel.com\/pt\/wall-mounted-vs-floor-mounted-distribution-boxes\/#Floor-Mounted_Distribution_Box-9\" >Floor-Mounted Distribution Box\u00a0<\/a><\/li><\/ul><\/li><li class='ez-toc-page-1 ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-31\" href=\"https:\/\/www.kdmsteel.com\/pt\/wall-mounted-vs-floor-mounted-distribution-boxes\/#Flexibility_Scalability\" >Flexibility &amp; Scalability<\/a><ul class='ez-toc-list-level-4' ><li class='ez-toc-heading-level-4'><a class=\"ez-toc-link ez-toc-heading-32\" href=\"https:\/\/www.kdmsteel.com\/pt\/wall-mounted-vs-floor-mounted-distribution-boxes\/#Wall-Mounted_Distribution_Box-10\" >Wall-Mounted Distribution Box<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-4'><a class=\"ez-toc-link ez-toc-heading-33\" href=\"https:\/\/www.kdmsteel.com\/pt\/wall-mounted-vs-floor-mounted-distribution-boxes\/#Floor-Mounted_Distribution_Box-10\" >Floor-Mounted Distribution Box<\/a><\/li><\/ul><\/li><\/ul><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-34\" href=\"https:\/\/www.kdmsteel.com\/pt\/wall-mounted-vs-floor-mounted-distribution-boxes\/#Side-by-Side_Comparison_Table\" >Side-by-Side Comparison Table<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-35\" href=\"https:\/\/www.kdmsteel.com\/pt\/wall-mounted-vs-floor-mounted-distribution-boxes\/#Wall-Mounted_vs_Floor-Mounted_Distribution_Boxes_%E2%80%94_Which_One_Should_You_Choose\" >Wall-Mounted vs Floor-Mounted Distribution Boxes \u2014 Which One Should You Choose?<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-36\" href=\"https:\/\/www.kdmsteel.com\/pt\/wall-mounted-vs-floor-mounted-distribution-boxes\/#Customized_Distribution_Boxes_by_KDM_Steel\" >Customized Distribution Boxes by KDM Steel<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-37\" href=\"https:\/\/www.kdmsteel.com\/pt\/wall-mounted-vs-floor-mounted-distribution-boxes\/#FAQs\" >Perguntas frequentes<\/a><ul class='ez-toc-list-level-3' ><li class='ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-38\" href=\"https:\/\/www.kdmsteel.com\/pt\/wall-mounted-vs-floor-mounted-distribution-boxes\/#Can_a_distribution_boxs_wall-mounted_vs_floor-mounted_design_affect_safety\" >Can a distribution box&#8217;s wall-mounted vs floor-mounted design affect safety?<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-39\" href=\"https:\/\/www.kdmsteel.com\/pt\/wall-mounted-vs-floor-mounted-distribution-boxes\/#Is_it_easier_to_place_distribution_boxes_that_are_mounted_on_the_wall_or_the_floor\" >Is it easier to place distribution boxes that are mounted on the wall or the floor?<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-40\" href=\"https:\/\/www.kdmsteel.com\/pt\/wall-mounted-vs-floor-mounted-distribution-boxes\/#Do_distribution_boxes_that_are_placed_on_the_floor_need_a_special_base_or_leveling\" >Do distribution boxes that are placed on the floor need a special base or leveling?<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-41\" href=\"https:\/\/www.kdmsteel.com\/pt\/wall-mounted-vs-floor-mounted-distribution-boxes\/#If_you_put_distribution_boxes_on_the_floor_or_the_wall_can_you_use_them_outside\" >If you put distribution boxes on the floor or the wall, can you use them outside?<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-42\" href=\"https:\/\/www.kdmsteel.com\/pt\/wall-mounted-vs-floor-mounted-distribution-boxes\/#Which_is_better_for_growth_a_distribution_box_placed_on_the_wall_or_the_floor\" >Which is better for growth: a distribution box placed on the wall or the floor?<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-43\" href=\"https:\/\/www.kdmsteel.com\/pt\/wall-mounted-vs-floor-mounted-distribution-boxes\/#Can_the_fact_that_a_distribution_box_is_placed_on_the_wall_or_the_floor_affect_fire_safety\" >Can the fact that a distribution box is placed on the wall or the floor affect fire safety?<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-44\" href=\"https:\/\/www.kdmsteel.com\/pt\/wall-mounted-vs-floor-mounted-distribution-boxes\/#When_it_comes_to_wall-mounted_vs_floor-mounted_distribution_boxes_what_kinds_of_materials_are_most_often_used\" >When it comes to wall-mounted vs. floor-mounted distribution boxes, what kinds of materials are most often used?<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-45\" href=\"https:\/\/www.kdmsteel.com\/pt\/wall-mounted-vs-floor-mounted-distribution-boxes\/#Are_there_different_IPNEMA_standards_for_wall-mounted_and_floor-mounted_distribution_boxes\" >Are there different IP\/NEMA standards for wall-mounted and floor-mounted distribution boxes?<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-46\" href=\"https:\/\/www.kdmsteel.com\/pt\/wall-mounted-vs-floor-mounted-distribution-boxes\/#Can_a_distribution_box_that_is_placed_on_the_wall_handle_high-current_tasks\" >Can a distribution box that is placed on the wall handle high-current tasks?<\/a><\/li><\/ul><\/li><\/ul><\/nav><\/div>\n<h2><span class=\"ez-toc-section\" id=\"What_Is_a_Wall-Mounted_Distribution_Box\"><\/span><strong>What Is a Wall-Mounted Distribution Box?<\/strong><span class=\"ez-toc-section-end\"><\/span><\/h2>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-full wp-image-50622\" src=\"http:\/\/www.kdmsteel.com\/wp-content\/uploads\/2026\/04\/What-Is-a-Wall-Mounted-Distribution-Box.jpg\" alt=\"What Is a Wall-Mounted Distribution Box\" width=\"1280\" height=\"720\" srcset=\"https:\/\/www.kdmsteel.com\/wp-content\/uploads\/2026\/04\/What-Is-a-Wall-Mounted-Distribution-Box.jpg 1280w, https:\/\/www.kdmsteel.com\/wp-content\/uploads\/2026\/04\/What-Is-a-Wall-Mounted-Distribution-Box-150x84.jpg 150w, https:\/\/www.kdmsteel.com\/wp-content\/uploads\/2026\/04\/What-Is-a-Wall-Mounted-Distribution-Box-768x432.jpg 768w, https:\/\/www.kdmsteel.com\/wp-content\/uploads\/2026\/04\/What-Is-a-Wall-Mounted-Distribution-Box-18x10.jpg 18w\" sizes=\"auto, (max-width: 1280px) 100vw, 1280px\" \/><\/p>\n<p>A wall-mounted distribution box is an electrical structure that is attached directly to a vertical surface. It usually holds control devices, <a href=\"https:\/\/www.kdmsteel.com\/pt\/disjuntores-600v-dc\/\"><strong>600V DC circuit breakers<\/strong><\/a>, and contactors. These small units are sealed on six sides and have pre-designed knockout points for cables to enter. This makes them perfect for spreading power in business and light industrial settings without a central hub.<\/p>\n<h2><span class=\"ez-toc-section\" id=\"What_Is_a_Floor-Mounted_Distribution_Box\"><\/span><strong>What Is a Floor-Mounted Distribution Box?<\/strong><span class=\"ez-toc-section-end\"><\/span><\/h2>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-full wp-image-50623\" src=\"http:\/\/www.kdmsteel.com\/wp-content\/uploads\/2026\/04\/What-Is-a-Floor-Mounted-Distribution-Box.jpg\" alt=\"What Is a Floor-Mounted Distribution Box\" width=\"1280\" height=\"720\" srcset=\"https:\/\/www.kdmsteel.com\/wp-content\/uploads\/2026\/04\/What-Is-a-Floor-Mounted-Distribution-Box.jpg 1280w, https:\/\/www.kdmsteel.com\/wp-content\/uploads\/2026\/04\/What-Is-a-Floor-Mounted-Distribution-Box-150x84.jpg 150w, https:\/\/www.kdmsteel.com\/wp-content\/uploads\/2026\/04\/What-Is-a-Floor-Mounted-Distribution-Box-768x432.jpg 768w, https:\/\/www.kdmsteel.com\/wp-content\/uploads\/2026\/04\/What-Is-a-Floor-Mounted-Distribution-Box-18x10.jpg 18w\" sizes=\"auto, (max-width: 1280px) 100vw, 1280px\" \/><\/p>\n<p>Floor-mounted distribution boxes are enclosures that stand alone and are put on the floor, usually against walls or in electric-only rooms. These strong cabinets have an open bottom and five sides that seal. They can hold bigger electrical assemblies, busbar systems, and high-capacity <a href=\"https:\/\/en.wikipedia.org\/wiki\/Switchgear\"><strong>aparelhagem de manobra<\/strong><\/a> for industrial buildings&#8217; main power distribution.<\/p>\n<h2><span class=\"ez-toc-section\" id=\"Side-by-Side_Comparison_between_Wall-Mounted_vs_Floor-Mounted_Distribution_Boxes\"><\/span><strong>Side-by-Side Comparison between Wall-Mounted vs Floor-Mounted Distribution Boxes<\/strong><span class=\"ez-toc-section-end\"><\/span><\/h2>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-full wp-image-50624\" src=\"http:\/\/www.kdmsteel.com\/wp-content\/uploads\/2026\/04\/Side-by-Side-Comparison-between-Wall-Mounted-vs-Floor-Mounted-Distribution-Boxes.jpg\" alt=\"Side-by-Side Comparison between Wall-Mounted vs Floor-Mounted Distribution Boxes\" width=\"1280\" height=\"720\" srcset=\"https:\/\/www.kdmsteel.com\/wp-content\/uploads\/2026\/04\/Side-by-Side-Comparison-between-Wall-Mounted-vs-Floor-Mounted-Distribution-Boxes.jpg 1280w, https:\/\/www.kdmsteel.com\/wp-content\/uploads\/2026\/04\/Side-by-Side-Comparison-between-Wall-Mounted-vs-Floor-Mounted-Distribution-Boxes-150x84.jpg 150w, https:\/\/www.kdmsteel.com\/wp-content\/uploads\/2026\/04\/Side-by-Side-Comparison-between-Wall-Mounted-vs-Floor-Mounted-Distribution-Boxes-768x432.jpg 768w, https:\/\/www.kdmsteel.com\/wp-content\/uploads\/2026\/04\/Side-by-Side-Comparison-between-Wall-Mounted-vs-Floor-Mounted-Distribution-Boxes-18x10.jpg 18w\" sizes=\"auto, (max-width: 1280px) 100vw, 1280px\" \/><\/p>\n<h3><span class=\"ez-toc-section\" id=\"Mounting_Method_Physical_Support\"><\/span><strong>Mounting Method &amp; Physical Support<\/strong><span class=\"ez-toc-section-end\"><\/span><\/h3>\n<h4><span class=\"ez-toc-section\" id=\"Wall-Mounted_Distribution_Box\"><\/span><strong>Wall-Mounted Distribution Box<\/strong><span class=\"ez-toc-section-end\"><\/span><\/h4>\n<p>These covers need to be securely attached to the walls of the building using expansion bolts or through-wall fasteners. Before placement, you&#8217;ll need to check the wall&#8217;s composition and its ability to hold weight. The height of the mounting usually puts the working handles at easy-to-reach heights. Cables enter through the top or bottom knockouts to keep the look clean and organized.<\/p>\n<h4><span class=\"ez-toc-section\" id=\"Floor-Mounted_Distribution_Box\"><\/span><strong>Floor-Mounted Distribution Box<\/strong><span class=\"ez-toc-section-end\"><\/span><\/h4>\n<p>These units stand on their own on floors that have been prepared, with their weight being spread out by base supports, also called plinths. You need to make sure the floor is level and, if possible, think about integrating a higher access floor. The bottom opening design lets large cable formations happen, and units usually need to be 5\u201310 mm above the finished floor level to keep water out.<\/p>\n<h3><span class=\"ez-toc-section\" id=\"Space_Utilization\"><\/span><strong>Space Utilization<\/strong><span class=\"ez-toc-section-end\"><\/span><\/h3>\n<h4><span class=\"ez-toc-section\" id=\"Wall-Mounted_Distribution_Box-2\"><\/span><strong>Wall-Mounted Distribution Box<\/strong><span class=\"ez-toc-section-end\"><\/span><\/h4>\n<p>These barriers work great in places where floor space is very valuable. You can save important production areas, aisles, and equipment staging areas by using vertical wall space. They work best in places with a lot of people, like stores, buildings with crowded floors, and places with many floors where every square meter counts for efficiency.<\/p>\n<h4><span class=\"ez-toc-section\" id=\"Floor-Mounted_Distribution_Box-2\"><\/span><strong>Floor-Mounted Distribution Box<\/strong><span class=\"ez-toc-section-end\"><\/span><\/h4>\n<p>Even though they take up valuable floor space, these cabinets make the most of vertical room by having multiple compartments. You can organize large electrical systems within a single footprint, which is helpful because the systems usually have different sections for control, distribution, and input. When handling complicated power distribution architectures, this consolidation is very helpful.<\/p>\n<h3><span class=\"ez-toc-section\" id=\"Capacity_Internal_Volume\"><\/span><strong>Capacity &amp; Internal Volume<\/strong><span class=\"ez-toc-section-end\"><\/span><\/h3>\n<h4><span class=\"ez-toc-section\" id=\"Wall-Mounted_Distribution_Box-3\"><\/span><strong>Wall-Mounted Distribution Box<\/strong><span class=\"ez-toc-section-end\"><\/span><\/h4>\n<p>Standardized sizes usually fall between 250x250x140mm and 1000x800x300mm, which can fit parts with modest densities. These can be used for lighting control, branch circuit distribution, and power sources that are specific to equipment. But as the number of components inside these small enclosures grows, thermal control becomes very important.<\/p>\n<h4><span class=\"ez-toc-section\" id=\"Floor-Mounted_Distribution_Box-3\"><\/span><strong>Floor-Mounted Distribution Box<\/strong><span class=\"ez-toc-section-end\"><\/span><\/h4>\n<p>With common dimensions of 1910x600x250mm and weight capacities of up to 800kg, these enclosures have much bigger interior volumes. Main switchgear, transformer banks, and large busbar systems can all be put together in one unit. The large interior room makes it easier for the conductors to bend properly, for heat to escape, and for future changes to be made without affecting accessibility.<\/p>\n<h3><span class=\"ez-toc-section\" id=\"Load-Bearing_Equipment_Weight\"><\/span><strong>Load-Bearing &amp; Equipment Weight<\/strong><span class=\"ez-toc-section-end\"><\/span><\/h3>\n<h4><span class=\"ez-toc-section\" id=\"Wall-Mounted_Distribution_Box-4\"><\/span><strong>Wall-Mounted Distribution Box<\/strong><span class=\"ez-toc-section-end\"><\/span><\/h4>\n<p>You must not go over the weight limits that are written on these boxes. A normal steel wall-mount unit can easily hold up to 40 kg of equipment inside. Heavy parts, like big transformers or a lot of breaker sections, quickly go over these limits. You&#8217;ll need to carefully figure out how much weight is being installed and make sure that the way the wall is built gives it enough anchoring power.<\/p>\n<h4><span class=\"ez-toc-section\" id=\"Floor-Mounted_Distribution_Box-4\"><\/span><strong>Floor-Mounted Distribution Box<\/strong><span class=\"ez-toc-section-end\"><\/span><\/h4>\n<p>Built on heavy-gauge steel frames that are welded together, floor-standing cabinets can hold a lot more weight\u2014often 800 kg or more. Since the weight is directly on the floor, there are no worries about fixing it to the wall. With this much space, you can put huge switchgear, busway systems, and many meter banks inside a single container without affecting its structural integrity.<\/p>\n<h3><span class=\"ez-toc-section\" id=\"Accessibility_Maintenance\"><\/span><strong>Accessibility &amp; Maintenance<\/strong><span class=\"ez-toc-section-end\"><\/span><\/h3>\n<h4><span class=\"ez-toc-section\" id=\"Wall-Mounted_Distribution_Box-5\"><\/span><strong>Wall-Mounted Distribution Box<\/strong><span class=\"ez-toc-section-end\"><\/span><\/h4>\n<p>The operating handles on these units are usually between 1.2 and 1.5 meters above the floor, which makes it easy to work on the parts. With front-access designs, upkeep can be done without having to bend over or stoop. But deep enclosures can make it hard to get to the back parts, and you might have to disconnect the wires just to get to the inside parts.<\/p>\n<h4><span class=\"ez-toc-section\" id=\"Floor-Mounted_Distribution_Box-5\"><\/span><strong>Floor-Mounted Distribution Box<\/strong><span class=\"ez-toc-section-end\"><\/span><\/h4>\n<p>The best internal design puts vertical busbars on the side (either the left or right) instead of in the back. This side-by-side setup makes it easier to get to connections and lets you use infrared thermography, which is important for preventive maintenance programs. With front-and-rear access configurations, you can fix parts without having to shut down whole areas.<\/p>\n<h3><span class=\"ez-toc-section\" id=\"Application_Complexity\"><\/span><strong>Application Complexity<\/strong><span class=\"ez-toc-section-end\"><\/span><\/h3>\n<h4><span class=\"ez-toc-section\" id=\"Wall-Mounted_Distribution_Box-6\"><\/span><strong>Wall-Mounted Distribution Box<\/strong><span class=\"ez-toc-section-end\"><\/span><\/h4>\n<p>These work great for simple distribution tasks like branch circuits, lighting panels, and power sources that are specific to equipment. Most of the time, they can handle up to 800A. When used in residential areas, compact designs put safety and good looks first. Modular options can handle a variety of loads in business buildings, such as data, power, and lighting.<\/p>\n<h4><span class=\"ez-toc-section\" id=\"Floor-Mounted_Distribution_Box-6\"><\/span><strong>Floor-Mounted Distribution Box<\/strong><span class=\"ez-toc-section-end\"><\/span><\/h4>\n<p>Floor-mounted cabinets are the way to go when your project needs major switchgear, large busbar systems, or Form 2b segregation (separating busbars from functional units). They can handle complicated incoming setups (top or bottom feed) and have separate cableways for circuits that are going out. Being able to hold high-voltage devices and handle mechanical stress is helpful in industrial settings.<\/p>\n<h3><span class=\"ez-toc-section\" id=\"Aesthetic_Integration\"><\/span><strong>Aesthetic Integration<\/strong><span class=\"ez-toc-section-end\"><\/span><\/h3>\n<h4><span class=\"ez-toc-section\" id=\"Wall-Mounted_Distribution_Box-7\"><\/span><strong>Wall-Mounted Distribution Box<\/strong><span class=\"ez-toc-section-end\"><\/span><\/h4>\n<p>Powder-coated finishes (often <a href=\"https:\/\/en.wikipedia.org\/wiki\/RAL_colour_standard\"><strong>RAL standard<\/strong><\/a> 9016 or 7035) on modern wall-mount cabinets make them look good in business settings. You can recess units into walls for a cleaner look with slim profiles and flush-mount choices. You can keep things looking professional in an office or store without sacrificing usefulness.<\/p>\n<h4><span class=\"ez-toc-section\" id=\"Floor-Mounted_Distribution_Box-7\"><\/span><strong>Floor-Mounted Distribution Box<\/strong><span class=\"ez-toc-section-end\"><\/span><\/h4>\n<p>People will notice these bigger shelves. Gray RAL 7035 finishes are normal from the manufacturer, but you&#8217;ll usually find them in utility rooms or electrical rooms where looks are less important. Their industrial look works well in service hallways and factory floors, but they should be placed carefully so they don&#8217;t stand out too much in finished rooms.<\/p>\n<h3><span class=\"ez-toc-section\" id=\"Structural_Installation_Requirements\"><\/span><strong>Structural &amp; Installation Requirements<\/strong><span class=\"ez-toc-section-end\"><\/span><\/h3>\n<h4><span class=\"ez-toc-section\" id=\"Wall-Mounted_Distribution_Box-8\"><\/span><strong>Wall-Mounted Distribution Box<\/strong><span class=\"ez-toc-section-end\"><\/span><\/h4>\n<p>Before placing, make sure the wall can hold the weight of the unit. Most main distribution units weigh between 10 and 15 kg when they&#8217;re empty, not counting the parts that are inside. Keep the minimum distances between things at least 150 mm above and below, and 50 mm to the right for air flow and work space. Pre-engineered knockouts make it easier for cables to get in, but wall penetration needs to be coordinated with the structure of the building.<\/p>\n<h4><span class=\"ez-toc-section\" id=\"Floor-Mounted_Distribution_Box-8\"><\/span><strong>Floor-Mounted Distribution Box<\/strong><span class=\"ez-toc-section-end\"><\/span><\/h4>\n<p>Preparing the floor is the first step in installation. For this, you&#8217;ll need flat areas that can hold heavy loads. Most of the time, these cabinets need to be 5\u201310 mm above the finished floor to keep water out. For bottom cable entries, you need to carefully plan how to penetrate the floor or use raised access floor solutions. To link several cabinets together, the sections must be perfectly lined up and connected by busbars.<\/p>\n<h3><span class=\"ez-toc-section\" id=\"Cost_Complexity\"><\/span><strong>Cost &amp; Complexity<\/strong><span class=\"ez-toc-section-end\"><\/span><\/h3>\n<h4><span class=\"ez-toc-section\" id=\"Wall-Mounted_Distribution_Box-9\"><\/span><strong>Wall-Mounted Distribution Box\u00a0<\/strong><span class=\"ez-toc-section-end\"><\/span><\/h4>\n<p>These units are usually the more affordable choice because they require less material and are easier to set up. You&#8217;ll save money on things like base work, renting a crane, and special rigging. But think about the hidden costs: having a lot of smaller enclosures spread out in different parts of your building may mean longer wire runs and more work to make sure that all the units work together.<\/p>\n<h4><span class=\"ez-toc-section\" id=\"Floor-Mounted_Distribution_Box-9\"><\/span><strong>Floor-Mounted Distribution Box\u00a0<\/strong><span class=\"ez-toc-section-end\"><\/span><\/h4>\n<p>The original cost is higher because it has more materials, heavier steel, and more complex internal busbar systems. For installation, the floor needs to be carefully prepared; there may need to be raised entry flooring, and mechanical handling equipment is sometimes needed. Still, you get long-term value from having easy access to upkeep, fewer copper runs because incoming supplies are centralized, and longer service life because the building is strong.<\/p>\n<h3><span class=\"ez-toc-section\" id=\"Flexibility_Scalability\"><\/span><strong>Flexibility &amp; Scalability<\/strong><span class=\"ez-toc-section-end\"><\/span><\/h3>\n<h4><span class=\"ez-toc-section\" id=\"Wall-Mounted_Distribution_Box-10\"><\/span><strong>Wall-Mounted Distribution Box<\/strong><span class=\"ez-toc-section-end\"><\/span><\/h4>\n<p>Within the limits of their structure, these enclosures allow for some freedom. You can add breakers to pre-configured train systems or switch out parts, but if you need to expand, you have to add another box because the enclosure can&#8217;t hold any more space. This &#8220;distributed&#8221; method might make phased growth easier for facilities that are getting bigger\u2014just add another wall-mount unit near the new equipment.<\/p>\n<h4><span class=\"ez-toc-section\" id=\"Floor-Mounted_Distribution_Box-10\"><\/span><strong>Floor-Mounted Distribution Box<\/strong><span class=\"ez-toc-section-end\"><\/span><\/h4>\n<p>This is the best place for floor-standing shelves. Most designs leave 20 to 30 percent of their busbar ratings and compartment room empty in case more circuits are added in the future. By connecting extra cabinets to current ones and extending the busbars through factory-engineered connections, you can add whole sections. Because they are easier to expand, large industrial sites often choose floor-mounted main distribution.<\/p>\n<h2><span class=\"ez-toc-section\" id=\"Side-by-Side_Comparison_Table\"><\/span><strong>Side-by-Side Comparison Table<\/strong><span class=\"ez-toc-section-end\"><\/span><\/h2>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-full wp-image-50630\" src=\"http:\/\/www.kdmsteel.com\/wp-content\/uploads\/2026\/04\/Side-by-Side-Comparison-Table.jpg\" alt=\"Side-by-Side Comparison Table\" width=\"1280\" height=\"720\" srcset=\"https:\/\/www.kdmsteel.com\/wp-content\/uploads\/2026\/04\/Side-by-Side-Comparison-Table.jpg 1280w, https:\/\/www.kdmsteel.com\/wp-content\/uploads\/2026\/04\/Side-by-Side-Comparison-Table-150x84.jpg 150w, https:\/\/www.kdmsteel.com\/wp-content\/uploads\/2026\/04\/Side-by-Side-Comparison-Table-768x432.jpg 768w, https:\/\/www.kdmsteel.com\/wp-content\/uploads\/2026\/04\/Side-by-Side-Comparison-Table-18x10.jpg 18w\" sizes=\"auto, (max-width: 1280px) 100vw, 1280px\" \/><\/p>\n<table width=\"684\">\n<tbody>\n<tr>\n<td><strong>Recurso<\/strong><\/td>\n<td><strong>Wall-Mounted Distribution Box<\/strong><\/td>\n<td><strong>Floor-Mounted Distribution Box<\/strong><\/td>\n<\/tr>\n<tr>\n<td><strong>Mounting Method<\/strong><\/td>\n<td>Secured to vertical structural walls<\/td>\n<td>Freestanding on a prepared floor surface<\/td>\n<\/tr>\n<tr>\n<td><strong>Typical Size Range<\/strong><\/td>\n<td>250\u00d7250\u00d7140mm to 1000\u00d7800\u00d7300mm<\/td>\n<td>Up to 1910\u00d7600\u00d7250mm and larger<\/td>\n<\/tr>\n<tr>\n<td><strong>Capacidade de peso<\/strong><\/td>\n<td>~40 kg typical maximum<\/td>\n<td>Up to 800 kg or more<\/td>\n<\/tr>\n<tr>\n<td><strong>Space Utilization<\/strong><\/td>\n<td>Preserves floor space, uses vertical wall area<\/td>\n<td>Requires a dedicated floor footprint, optimizes vertical stacking<\/td>\n<\/tr>\n<tr>\n<td><strong>Typical Applications<\/strong><\/td>\n<td>Branch circuits, lighting panels, and equipment power<\/td>\n<td>Main switchgear, busbar systems, and high-capacity distribution<\/td>\n<\/tr>\n<tr>\n<td><strong>Current Rating<\/strong><\/td>\n<td>Typically up to 800A<\/td>\n<td>Can exceed 2000A with busbar systems<\/td>\n<\/tr>\n<tr>\n<td><strong>Requisitos de instala\u00e7\u00e3o<\/strong><\/td>\n<td>Wall anchoring, accessible height placement<\/td>\n<td>Level floor prep, potential raised access, 5-10mm elevation<\/td>\n<\/tr>\n<tr>\n<td><strong>Acessibilidade<\/strong><\/td>\n<td>Front access is typical; rear components may be constrained<\/td>\n<td>Front\/rear access options, lateral busbar placement for easy maintenance<\/td>\n<\/tr>\n<tr>\n<td><strong>Escalabilidade<\/strong><\/td>\n<td>Limited to enclosure volume; add units for expansion<\/td>\n<td>Highly scalable; add coupled sections with busbar extensions<\/td>\n<\/tr>\n<tr>\n<td><strong>Relative Cost<\/strong><\/td>\n<td>Lower initial investment<\/td>\n<td>Higher initial investment, greater long-term value<\/td>\n<\/tr>\n<tr>\n<td><strong>Aesthetic Integration<\/strong><\/td>\n<td>Can blend with interiors; flush-mount options available<\/td>\n<td>Industrial appearance, typically located in electrical rooms<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h2><span class=\"ez-toc-section\" id=\"Wall-Mounted_vs_Floor-Mounted_Distribution_Boxes_%E2%80%94_Which_One_Should_You_Choose\"><\/span><strong>Wall-Mounted vs Floor-Mounted Distribution Boxes \u2014 Which One Should You Choose?<\/strong><span class=\"ez-toc-section-end\"><\/span><\/h2>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-full wp-image-50625\" src=\"http:\/\/www.kdmsteel.com\/wp-content\/uploads\/2026\/04\/Wall-Mounted-vs-Floor-Mounted-Distribution-Boxes-\u2014-Which-One-Should-You-Choose.jpg\" alt=\"Wall-Mounted vs Floor-Mounted Distribution Boxes \u2014 Which One Should You Choose\" width=\"1280\" height=\"720\" srcset=\"https:\/\/www.kdmsteel.com\/wp-content\/uploads\/2026\/04\/Wall-Mounted-vs-Floor-Mounted-Distribution-Boxes-\u2014-Which-One-Should-You-Choose.jpg 1280w, https:\/\/www.kdmsteel.com\/wp-content\/uploads\/2026\/04\/Wall-Mounted-vs-Floor-Mounted-Distribution-Boxes-\u2014-Which-One-Should-You-Choose-150x84.jpg 150w, https:\/\/www.kdmsteel.com\/wp-content\/uploads\/2026\/04\/Wall-Mounted-vs-Floor-Mounted-Distribution-Boxes-\u2014-Which-One-Should-You-Choose-768x432.jpg 768w, https:\/\/www.kdmsteel.com\/wp-content\/uploads\/2026\/04\/Wall-Mounted-vs-Floor-Mounted-Distribution-Boxes-\u2014-Which-One-Should-You-Choose-18x10.jpg 18w\" sizes=\"auto, (max-width: 1280px) 100vw, 1280px\" \/><\/p>\n<p>Your choice will depend on the size of the project and the priorities of the customers. Wall-mounted boxes are best for places with limited floor space, decentralized uses, and current needs that are less than 800A. They are perfect for multi-story buildings, retail spaces, and distributing equipment.<\/p>\n<p>Choose floor-mounted cabinets if you need equipment for the main service entrance, high-capacity busbar systems, or the ability to expand in the future. This is especially important for industrial plants, big commercial complexes, and buildings with centralized power distribution systems. You could also use a hybrid method, with mains that are mounted on the floor and sub-distribution units that are mounted on the walls all over your building.<\/p>\n<h2><span class=\"ez-toc-section\" id=\"Customized_Distribution_Boxes_by_KDM_Steel\"><\/span><strong>Customized Distribution Boxes by KDM Steel<\/strong><span class=\"ez-toc-section-end\"><\/span><\/h2>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-full wp-image-50626\" src=\"http:\/\/www.kdmsteel.com\/wp-content\/uploads\/2026\/04\/Customized-Distribution-Boxes-by-KDM-Steel.jpg\" alt=\"Customized Distribution Boxes by KDM Steel\" width=\"1280\" height=\"720\" srcset=\"https:\/\/www.kdmsteel.com\/wp-content\/uploads\/2026\/04\/Customized-Distribution-Boxes-by-KDM-Steel.jpg 1280w, https:\/\/www.kdmsteel.com\/wp-content\/uploads\/2026\/04\/Customized-Distribution-Boxes-by-KDM-Steel-150x84.jpg 150w, https:\/\/www.kdmsteel.com\/wp-content\/uploads\/2026\/04\/Customized-Distribution-Boxes-by-KDM-Steel-768x432.jpg 768w, https:\/\/www.kdmsteel.com\/wp-content\/uploads\/2026\/04\/Customized-Distribution-Boxes-by-KDM-Steel-18x10.jpg 18w\" sizes=\"auto, (max-width: 1280px) 100vw, 1280px\" \/><\/p>\n<p>Every project has its own problems, like limitations on the building&#8217;s space, odd-shaped parts, or special environmental needs. <a href=\"https:\/\/www.kdmsteel.com\/pt\/\">A\u00e7o KDM<\/a> makes custom distribution boxes that are built to your exact specs. Our team can help you with CAD-supported engineering and quick production, whether you need wall-mounted enclosures with specific cutouts, floor-standing cabinets with Form 4b segregation, or changes to standard IP-rated designs. Check out our mounting tools and accessories to finish your installation like a professional. <a href=\"https:\/\/www.kdmsteel.com\/pt\/contato\/\"><strong>Contate-nos<\/strong><\/a> to get further details.<\/p>\n<h2><span class=\"ez-toc-section\" id=\"FAQs\"><\/span><strong>Perguntas frequentes<\/strong><span class=\"ez-toc-section-end\"><\/span><\/h2>\n<h3><span class=\"ez-toc-section\" id=\"Can_a_distribution_boxs_wall-mounted_vs_floor-mounted_design_affect_safety\"><\/span><strong>Can a distribution box&#8217;s wall-mounted vs floor-mounted design affect safety?<\/strong><span class=\"ez-toc-section-end\"><\/span><\/h3>\n<p>Yes, units that are mounted on the wall need to be securely attached so that they don&#8217;t come loose during faults, and cabinets that are mounted on the floor need stable bases so that they can handle the electric forces that come from short-circuits.<\/p>\n<h3><span class=\"ez-toc-section\" id=\"Is_it_easier_to_place_distribution_boxes_that_are_mounted_on_the_wall_or_the_floor\"><\/span><strong>Is it easier to place distribution boxes that are mounted on the wall or the floor?<\/strong><span class=\"ez-toc-section-end\"><\/span><\/h3>\n<p>Yes. Standard tools are needed to fix wall-mounted units and connect their cables. For floor-mounted systems, the floor needs to be prepared and leveled, and mechanical handling equipment is often needed.<\/p>\n<h3><span class=\"ez-toc-section\" id=\"Do_distribution_boxes_that_are_placed_on_the_floor_need_a_special_base_or_leveling\"><\/span><strong>Do distribution boxes that are placed on the floor need a special base or leveling?<\/strong><span class=\"ez-toc-section-end\"><\/span><\/h3>\n<p>Yes, they do need floors that are flat and strong enough to hold heavy loads. To keep moisture out, many standards call for a 5\u201310 mm height above the finished floor.<\/p>\n<h3><span class=\"ez-toc-section\" id=\"If_you_put_distribution_boxes_on_the_floor_or_the_wall_can_you_use_them_outside\"><\/span><strong>If you put distribution boxes on the floor or the wall, can you use them outside?<\/strong><span class=\"ez-toc-section-end\"><\/span><\/h3>\n<p>Both can if they have the right IP or NEMA ratings look for<a href=\"https:\/\/www.kdmsteel.com\/pt\/gabinete-ip55\/\"> <strong>IP55<\/strong><\/a>, <a href=\"https:\/\/www.kdmsteel.com\/pt\/gabinete-ip66\/\"><strong>IP66,<\/strong><\/a> or NEMA 3R\/4\/4X. Units that are placed on the wall need rain shields, while cabinets that are mounted on the floor need plinth bases to keep water from pooling.<\/p>\n<h3><span class=\"ez-toc-section\" id=\"Which_is_better_for_growth_a_distribution_box_placed_on_the_wall_or_the_floor\"><\/span><strong>Which is better for growth: a distribution box placed on the wall or the floor?<\/strong><span class=\"ez-toc-section-end\"><\/span><\/h3>\n<p>With their modular design that lets you connect parts and add busbars, floor-mounted cabinets are clearly the winner. When the capacity is used up, wall-mounted units need to be completely replaced or have duplicate enclosures added.<\/p>\n<h3><span class=\"ez-toc-section\" id=\"Can_the_fact_that_a_distribution_box_is_placed_on_the_wall_or_the_floor_affect_fire_safety\"><\/span><strong>Can the fact that a distribution box is placed on the wall or the floor affect fire safety?<\/strong><span class=\"ez-toc-section-end\"><\/span><\/h3>\n<p>Yes. Floor-mounted units in electrical rooms have their own fire suppression systems, but wall-mounted units that are spread out across the building might not have this safety.<\/p>\n<h3><span class=\"ez-toc-section\" id=\"When_it_comes_to_wall-mounted_vs_floor-mounted_distribution_boxes_what_kinds_of_materials_are_most_often_used\"><\/span><strong>When it comes to wall-mounted vs. floor-mounted distribution boxes, what kinds of materials are most often used?<\/strong><span class=\"ez-toc-section-end\"><\/span><\/h3>\n<p>Both groups are dominated by mild steel that has been powder-coated. Heavy-duty floor-mounted applications usually use 2.0\u20132.5 mm steel, while normal wall-mounted units use 1.2\u20131.5 mm steel.<\/p>\n<h3><span class=\"ez-toc-section\" id=\"Are_there_different_IPNEMA_standards_for_wall-mounted_and_floor-mounted_distribution_boxes\"><\/span><strong>Are there different IP\/NEMA standards for wall-mounted and floor-mounted distribution boxes?<\/strong><span class=\"ez-toc-section-end\"><\/span><\/h3>\n<p>Both cover the whole range, from IP40 for indoor use to IP69K for wet areas. Your choice should be based on specific problems, like dust, moisture, high temperatures, or chemical exposure.<\/p>\n<h3><span class=\"ez-toc-section\" id=\"Can_a_distribution_box_that_is_placed_on_the_wall_handle_high-current_tasks\"><\/span><strong>Can a distribution box that is placed on the wall handle high-current tasks?<\/strong><span class=\"ez-toc-section-end\"><\/span><\/h3>\n<p>Most of the time, wall-mounted units can handle up to 800A. Besides this, floor-mounted designs give you the space, air flow, and busbar options you need to control temperature.<\/p>","protected":false},"excerpt":{"rendered":"<p>Choosing between wall-mounted vs floor-mounted distribution boxes can have a big effect on the safety, economy, and bottom line of your project. This guide helps you compare both choices based on installation needs, space limitations, and long-term operating requirements so you can make smart buying decisions. What Is a Wall-Mounted Distribution Box? A wall-mounted distribution [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":50627,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"site-sidebar-layout":"default","site-content-layout":"","ast-site-content-layout":"default","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"","ast-breadcrumbs-content":"disabled","ast-featured-img":"","footer-sml-layout":"","ast-disable-related-posts":"","theme-transparent-header-meta":"default","adv-header-id-meta":"","stick-header-meta":"default","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"set","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"footnotes":""},"categories":[1],"tags":[],"class_list":["post-50580","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-blog"],"acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v27.3 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>Wall-Mounted vs Floor-Mounted Distribution Boxes - KDM Steel<\/title>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.kdmsteel.com\/pt\/wall-mounted-vs-floor-mounted-distribution-boxes\/\" \/>\n<meta property=\"og:locale\" content=\"pt_PT\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Wall-Mounted vs Floor-Mounted Distribution Boxes - KDM Steel\" \/>\n<meta property=\"og:description\" content=\"Choosing between wall-mounted vs floor-mounted distribution boxes can have a big effect on the safety, economy, and bottom line of your project. This guide helps you compare both choices based on installation needs, space limitations, and long-term operating requirements so you can make smart buying decisions. What Is a Wall-Mounted Distribution Box? A wall-mounted distribution [&hellip;]\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.kdmsteel.com\/pt\/wall-mounted-vs-floor-mounted-distribution-boxes\/\" \/>\n<meta property=\"og:site_name\" content=\"KDM Steel\" \/>\n<meta property=\"article:published_time\" content=\"2026-04-02T08:12:44+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2026-04-03T16:34:07+00:00\" \/>\n<meta property=\"og:image\" content=\"http:\/\/www.kdmsteel.com\/wp-content\/uploads\/2026\/04\/Wall-Mounted-vs-Floor-Mounted-Distribution-Boxes.jpg\" \/>\n\t<meta property=\"og:image:width\" content=\"1280\" \/>\n\t<meta property=\"og:image:height\" content=\"720\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"author\" content=\"KDM Steel\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Escrito por\" \/>\n\t<meta name=\"twitter:data1\" content=\"KDM Steel\" \/>\n\t<meta name=\"twitter:label2\" content=\"Tempo estimado de leitura\" \/>\n\t<meta name=\"twitter:data2\" content=\"12 minutos\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\\\/\\\/www.kdmsteel.com\\\/wall-mounted-vs-floor-mounted-distribution-boxes\\\/#article\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.kdmsteel.com\\\/wall-mounted-vs-floor-mounted-distribution-boxes\\\/\"},\"author\":{\"name\":\"KDM Steel\",\"@id\":\"https:\\\/\\\/www.kdmsteel.com\\\/#\\\/schema\\\/person\\\/20f9dd106f5824b75813f83f5a192a5f\"},\"headline\":\"Wall-Mounted vs Floor-Mounted Distribution Boxes\",\"datePublished\":\"2026-04-02T08:12:44+00:00\",\"dateModified\":\"2026-04-03T16:34:07+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/www.kdmsteel.com\\\/wall-mounted-vs-floor-mounted-distribution-boxes\\\/\"},\"wordCount\":2361,\"commentCount\":0,\"publisher\":{\"@id\":\"https:\\\/\\\/www.kdmsteel.com\\\/#organization\"},\"image\":{\"@id\":\"https:\\\/\\\/www.kdmsteel.com\\\/wall-mounted-vs-floor-mounted-distribution-boxes\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/www.kdmsteel.com\\\/wp-content\\\/uploads\\\/2026\\\/04\\\/Wall-Mounted-vs-Floor-Mounted-Distribution-Boxes.jpg\",\"articleSection\":[\"Blog\"],\"inLanguage\":\"pt-PT\",\"potentialAction\":[{\"@type\":\"CommentAction\",\"name\":\"Comment\",\"target\":[\"https:\\\/\\\/www.kdmsteel.com\\\/wall-mounted-vs-floor-mounted-distribution-boxes\\\/#respond\"]}]},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/www.kdmsteel.com\\\/wall-mounted-vs-floor-mounted-distribution-boxes\\\/\",\"url\":\"https:\\\/\\\/www.kdmsteel.com\\\/wall-mounted-vs-floor-mounted-distribution-boxes\\\/\",\"name\":\"Wall-Mounted vs Floor-Mounted Distribution Boxes - KDM Steel\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.kdmsteel.com\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/www.kdmsteel.com\\\/wall-mounted-vs-floor-mounted-distribution-boxes\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/www.kdmsteel.com\\\/wall-mounted-vs-floor-mounted-distribution-boxes\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/www.kdmsteel.com\\\/wp-content\\\/uploads\\\/2026\\\/04\\\/Wall-Mounted-vs-Floor-Mounted-Distribution-Boxes.jpg\",\"datePublished\":\"2026-04-02T08:12:44+00:00\",\"dateModified\":\"2026-04-03T16:34:07+00:00\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/www.kdmsteel.com\\\/wall-mounted-vs-floor-mounted-distribution-boxes\\\/#breadcrumb\"},\"inLanguage\":\"pt-PT\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/www.kdmsteel.com\\\/wall-mounted-vs-floor-mounted-distribution-boxes\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"pt-PT\",\"@id\":\"https:\\\/\\\/www.kdmsteel.com\\\/wall-mounted-vs-floor-mounted-distribution-boxes\\\/#primaryimage\",\"url\":\"https:\\\/\\\/www.kdmsteel.com\\\/wp-content\\\/uploads\\\/2026\\\/04\\\/Wall-Mounted-vs-Floor-Mounted-Distribution-Boxes.jpg\",\"contentUrl\":\"https:\\\/\\\/www.kdmsteel.com\\\/wp-content\\\/uploads\\\/2026\\\/04\\\/Wall-Mounted-vs-Floor-Mounted-Distribution-Boxes.jpg\",\"width\":1280,\"height\":720},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/www.kdmsteel.com\\\/wall-mounted-vs-floor-mounted-distribution-boxes\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/www.kdmsteel.com\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Wall-Mounted vs Floor-Mounted Distribution Boxes\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/www.kdmsteel.com\\\/#website\",\"url\":\"https:\\\/\\\/www.kdmsteel.com\\\/\",\"name\":\"KDM Steel\",\"description\":\"\",\"publisher\":{\"@id\":\"https:\\\/\\\/www.kdmsteel.com\\\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/www.kdmsteel.com\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"pt-PT\"},{\"@type\":\"Organization\",\"@id\":\"https:\\\/\\\/www.kdmsteel.com\\\/#organization\",\"name\":\"KDM Steel\",\"url\":\"https:\\\/\\\/www.kdmsteel.com\\\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"pt-PT\",\"@id\":\"https:\\\/\\\/www.kdmsteel.com\\\/#\\\/schema\\\/logo\\\/image\\\/\",\"url\":\"https:\\\/\\\/www.kdmsteel.com\\\/wp-content\\\/uploads\\\/2024\\\/05\\\/cropped-kdmsteel-logo.png\",\"contentUrl\":\"https:\\\/\\\/www.kdmsteel.com\\\/wp-content\\\/uploads\\\/2024\\\/05\\\/cropped-kdmsteel-logo.png\",\"width\":998,\"height\":535,\"caption\":\"KDM Steel\"},\"image\":{\"@id\":\"https:\\\/\\\/www.kdmsteel.com\\\/#\\\/schema\\\/logo\\\/image\\\/\"}},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/www.kdmsteel.com\\\/#\\\/schema\\\/person\\\/20f9dd106f5824b75813f83f5a192a5f\",\"name\":\"KDM Steel\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"pt-PT\",\"@id\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/64b16d13078b1bec337dbb31f593dfd16bc530c88ca9fe9b1c9d2a002408080e?s=96&d=mm&r=g\",\"url\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/64b16d13078b1bec337dbb31f593dfd16bc530c88ca9fe9b1c9d2a002408080e?s=96&d=mm&r=g\",\"contentUrl\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/64b16d13078b1bec337dbb31f593dfd16bc530c88ca9fe9b1c9d2a002408080e?s=96&d=mm&r=g\",\"caption\":\"KDM Steel\"}}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"Wall-Mounted vs Floor-Mounted Distribution Boxes - KDM Steel","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.kdmsteel.com\/pt\/wall-mounted-vs-floor-mounted-distribution-boxes\/","og_locale":"pt_PT","og_type":"article","og_title":"Wall-Mounted vs Floor-Mounted Distribution Boxes - KDM Steel","og_description":"Choosing between wall-mounted vs floor-mounted distribution boxes can have a big effect on the safety, economy, and bottom line of your project. This guide helps you compare both choices based on installation needs, space limitations, and long-term operating requirements so you can make smart buying decisions. What Is a Wall-Mounted Distribution Box? A wall-mounted distribution [&hellip;]","og_url":"https:\/\/www.kdmsteel.com\/pt\/wall-mounted-vs-floor-mounted-distribution-boxes\/","og_site_name":"KDM Steel","article_published_time":"2026-04-02T08:12:44+00:00","article_modified_time":"2026-04-03T16:34:07+00:00","og_image":[{"width":1280,"height":720,"url":"http:\/\/www.kdmsteel.com\/wp-content\/uploads\/2026\/04\/Wall-Mounted-vs-Floor-Mounted-Distribution-Boxes.jpg","type":"image\/jpeg"}],"author":"KDM Steel","twitter_card":"summary_large_image","twitter_misc":{"Escrito por":"KDM Steel","Tempo estimado de leitura":"12 minutos"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/www.kdmsteel.com\/wall-mounted-vs-floor-mounted-distribution-boxes\/#article","isPartOf":{"@id":"https:\/\/www.kdmsteel.com\/wall-mounted-vs-floor-mounted-distribution-boxes\/"},"author":{"name":"KDM Steel","@id":"https:\/\/www.kdmsteel.com\/#\/schema\/person\/20f9dd106f5824b75813f83f5a192a5f"},"headline":"Wall-Mounted vs Floor-Mounted Distribution Boxes","datePublished":"2026-04-02T08:12:44+00:00","dateModified":"2026-04-03T16:34:07+00:00","mainEntityOfPage":{"@id":"https:\/\/www.kdmsteel.com\/wall-mounted-vs-floor-mounted-distribution-boxes\/"},"wordCount":2361,"commentCount":0,"publisher":{"@id":"https:\/\/www.kdmsteel.com\/#organization"},"image":{"@id":"https:\/\/www.kdmsteel.com\/wall-mounted-vs-floor-mounted-distribution-boxes\/#primaryimage"},"thumbnailUrl":"https:\/\/www.kdmsteel.com\/wp-content\/uploads\/2026\/04\/Wall-Mounted-vs-Floor-Mounted-Distribution-Boxes.jpg","articleSection":["Blog"],"inLanguage":"pt-PT","potentialAction":[{"@type":"CommentAction","name":"Comment","target":["https:\/\/www.kdmsteel.com\/wall-mounted-vs-floor-mounted-distribution-boxes\/#respond"]}]},{"@type":"WebPage","@id":"https:\/\/www.kdmsteel.com\/wall-mounted-vs-floor-mounted-distribution-boxes\/","url":"https:\/\/www.kdmsteel.com\/wall-mounted-vs-floor-mounted-distribution-boxes\/","name":"Wall-Mounted vs Floor-Mounted Distribution Boxes - KDM Steel","isPartOf":{"@id":"https:\/\/www.kdmsteel.com\/#website"},"primaryImageOfPage":{"@id":"https:\/\/www.kdmsteel.com\/wall-mounted-vs-floor-mounted-distribution-boxes\/#primaryimage"},"image":{"@id":"https:\/\/www.kdmsteel.com\/wall-mounted-vs-floor-mounted-distribution-boxes\/#primaryimage"},"thumbnailUrl":"https:\/\/www.kdmsteel.com\/wp-content\/uploads\/2026\/04\/Wall-Mounted-vs-Floor-Mounted-Distribution-Boxes.jpg","datePublished":"2026-04-02T08:12:44+00:00","dateModified":"2026-04-03T16:34:07+00:00","breadcrumb":{"@id":"https:\/\/www.kdmsteel.com\/wall-mounted-vs-floor-mounted-distribution-boxes\/#breadcrumb"},"inLanguage":"pt-PT","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.kdmsteel.com\/wall-mounted-vs-floor-mounted-distribution-boxes\/"]}]},{"@type":"ImageObject","inLanguage":"pt-PT","@id":"https:\/\/www.kdmsteel.com\/wall-mounted-vs-floor-mounted-distribution-boxes\/#primaryimage","url":"https:\/\/www.kdmsteel.com\/wp-content\/uploads\/2026\/04\/Wall-Mounted-vs-Floor-Mounted-Distribution-Boxes.jpg","contentUrl":"https:\/\/www.kdmsteel.com\/wp-content\/uploads\/2026\/04\/Wall-Mounted-vs-Floor-Mounted-Distribution-Boxes.jpg","width":1280,"height":720},{"@type":"BreadcrumbList","@id":"https:\/\/www.kdmsteel.com\/wall-mounted-vs-floor-mounted-distribution-boxes\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/www.kdmsteel.com\/"},{"@type":"ListItem","position":2,"name":"Wall-Mounted vs Floor-Mounted Distribution Boxes"}]},{"@type":"WebSite","@id":"https:\/\/www.kdmsteel.com\/#website","url":"https:\/\/www.kdmsteel.com\/","name":"A\u00e7o KDM","description":"","publisher":{"@id":"https:\/\/www.kdmsteel.com\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/www.kdmsteel.com\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"pt-PT"},{"@type":"Organization","@id":"https:\/\/www.kdmsteel.com\/#organization","name":"A\u00e7o KDM","url":"https:\/\/www.kdmsteel.com\/","logo":{"@type":"ImageObject","inLanguage":"pt-PT","@id":"https:\/\/www.kdmsteel.com\/#\/schema\/logo\/image\/","url":"https:\/\/www.kdmsteel.com\/wp-content\/uploads\/2024\/05\/cropped-kdmsteel-logo.png","contentUrl":"https:\/\/www.kdmsteel.com\/wp-content\/uploads\/2024\/05\/cropped-kdmsteel-logo.png","width":998,"height":535,"caption":"KDM Steel"},"image":{"@id":"https:\/\/www.kdmsteel.com\/#\/schema\/logo\/image\/"}},{"@type":"Person","@id":"https:\/\/www.kdmsteel.com\/#\/schema\/person\/20f9dd106f5824b75813f83f5a192a5f","name":"A\u00e7o KDM","image":{"@type":"ImageObject","inLanguage":"pt-PT","@id":"https:\/\/secure.gravatar.com\/avatar\/64b16d13078b1bec337dbb31f593dfd16bc530c88ca9fe9b1c9d2a002408080e?s=96&d=mm&r=g","url":"https:\/\/secure.gravatar.com\/avatar\/64b16d13078b1bec337dbb31f593dfd16bc530c88ca9fe9b1c9d2a002408080e?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/64b16d13078b1bec337dbb31f593dfd16bc530c88ca9fe9b1c9d2a002408080e?s=96&d=mm&r=g","caption":"KDM Steel"}}]}},"_links":{"self":[{"href":"https:\/\/www.kdmsteel.com\/pt\/wp-json\/wp\/v2\/posts\/50580","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.kdmsteel.com\/pt\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.kdmsteel.com\/pt\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.kdmsteel.com\/pt\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.kdmsteel.com\/pt\/wp-json\/wp\/v2\/comments?post=50580"}],"version-history":[{"count":5,"href":"https:\/\/www.kdmsteel.com\/pt\/wp-json\/wp\/v2\/posts\/50580\/revisions"}],"predecessor-version":[{"id":50631,"href":"https:\/\/www.kdmsteel.com\/pt\/wp-json\/wp\/v2\/posts\/50580\/revisions\/50631"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.kdmsteel.com\/pt\/wp-json\/wp\/v2\/media\/50627"}],"wp:attachment":[{"href":"https:\/\/www.kdmsteel.com\/pt\/wp-json\/wp\/v2\/media?parent=50580"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.kdmsteel.com\/pt\/wp-json\/wp\/v2\/categories?post=50580"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.kdmsteel.com\/pt\/wp-json\/wp\/v2\/tags?post=50580"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}