{"id":45227,"date":"2024-02-23T03:47:47","date_gmt":"2024-02-23T03:47:47","guid":{"rendered":"https:\/\/www.kdmsteel.com\/?p=45227"},"modified":"2024-02-23T03:47:47","modified_gmt":"2024-02-23T03:47:47","slug":"600v-dc-circuit-breakers","status":"publish","type":"post","link":"https:\/\/www.kdmsteel.com\/ko\/600v-dc-\ud68c\ub85c-\ucc28\ub2e8\uae30\/","title":{"rendered":"600V DC \ud68c\ub85c \ucc28\ub2e8\uae30"},"content":{"rendered":"<p>\uc774 \uc81c\ud488\uc740 \ubb3c\ub9ac\uc801 \ud06c\uae30\uac00 \ube44\uad50\uc801 \ud06c\uba70, 48V DC \ud68c\ub85c \ucc28\ub2e8\uae30\uc640 \ub2ec\ub9ac \ucd5c\ub300 600V DC\uae4c\uc9c0 \uc218\uc6a9\ud560 \uc218 \uc788\uc2b5\ub2c8\ub2e4. \uc77c\ubc18\uc801\uc73c\ub85c \ub300\uaddc\ubaa8 \uc0c1\uc5c5 \ubc0f \uc0b0\uc5c5 \ud50c\ub79c\ud2b8\uc5d0 \uc801\uc6a9\ub429\ub2c8\ub2e4. \ubb3c\ub860, \ub450 \uadf9 \uc0ac\uc774\uc758 \uc804\uc704\ucc28\uac00 600V\ub97c \ucd08\uacfc\ud558\uc9c0 \uc54a\ub294 \uc751\uc6a9 \ubd84\uc57c\uc5d0\ub3c4 \uc801\uc6a9\ub429\ub2c8\ub2e4.<\/p>\n<p>\ub530\ub77c\uc11c \uc774 \uc720\ud615\uc758 \ucc28\ub2e8\uae30\ub294 \uc9c0\uc815\ub41c \uc804\uc555\uc778 600V\ub97c \ucd08\uacfc\ud558\uba74 \uc791\ub3d9\ud558\uac8c \ub429\ub2c8\ub2e4.<\/p>\n<p>\ub610\ud55c 600V DC <a href=\"https:\/\/www.theengineerspost.com\/types-of-circuit-breakers\/\">\ud68c\ub85c \ucc28\ub2e8\uae30<\/a> \ub610\ud55c \uc2dc\uc2a4\ud15c\uc758 \ubaa9\uc801\uacfc \uc6a9\ub3c4\uc5d0 \ub530\ub77c \uad11\ubc94\uc704\ud55c \uc804\ub958 \uc815\uaca9\uc744 \uc218\uc6a9\ud558\ub3c4\ub85d \uc124\uacc4\ub418\uc5c8\uc2b5\ub2c8\ub2e4.<\/p>\n<figure id=\"attachment_45228\" aria-describedby=\"caption-attachment-45228\" style=\"width: 650px\" class=\"wp-caption aligncenter\"><img loading=\"lazy\" decoding=\"async\" class=\"size-full wp-image-45228\" src=\"http:\/\/www.kdmsteel.com\/wp-content\/uploads\/2024\/02\/Figure-1-Circuit-breaker-components-1.jpg\" alt=\"\ud68c\ub85c \ucc28\ub2e8\uae30 \uad6c\uc131 \uc694\uc18c\" width=\"650\" height=\"450\" srcset=\"https:\/\/www.kdmsteel.com\/wp-content\/uploads\/2024\/02\/Figure-1-Circuit-breaker-components-1.jpg 650w, https:\/\/www.kdmsteel.com\/wp-content\/uploads\/2024\/02\/Figure-1-Circuit-breaker-components-1-150x104.jpg 150w\" sizes=\"auto, (max-width: 650px) 100vw, 650px\" \/><figcaption id=\"caption-attachment-45228\" class=\"wp-caption-text\">\ud68c\ub85c \ucc28\ub2e8\uae30 \uad6c\uc131 \uc694\uc18c<\/figcaption><\/figure>\n<p>\uc608\ub97c \ub4e4\uc5b4, 600V DC \ud0dc\uc591\uad11 \ud328\ub110\uc758 \uc804\ub958 \uc815\uaca9\uc740 \uc81c\uc870\uc5c5\uccb4\uc5d0 \ub530\ub77c 16~20A\uc785\ub2c8\ub2e4. \ub9c8\ucc2c\uac00\uc9c0\ub85c, \uc124\uce58 \ubc0f \uc7a5\ucc29 \uae30\ubc95\uacfc \uac19\uc740 \ud2b9\uc815 \uc0ac\uc591\ub3c4 \uc6a9\ub3c4\uc5d0 \ub530\ub77c \ub2ec\ub77c\uc9c8 \uc218 \uc788\uc2b5\ub2c8\ub2e4.<\/p>","protected":false},"excerpt":{"rendered":"<p>They are relatively larger in terms of physical size and can accommodate a DC of up to 600 voltage as opposed to 48v DC circuit breakers. They are commonly applied in large-scale commercial and industrial plants. Of course in applications whose potential voltage difference between the two poles does not exceed 600v. As such, this [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":45229,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"site-sidebar-layout":"default","site-content-layout":"","ast-site-content-layout":"default","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"","ast-breadcrumbs-content":"","ast-featured-img":"disabled","footer-sml-layout":"","ast-disable-related-posts":"","theme-transparent-header-meta":"default","adv-header-id-meta":"","stick-header-meta":"default","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"set","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"footnotes":""},"categories":[1],"tags":[],"class_list":["post-45227","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-blog"],"acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v28.1 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>600V DC Circuit Breakers - KDM Steel<\/title>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.kdmsteel.com\/ko\/600v-dc-\ud68c\ub85c-\ucc28\ub2e8\uae30\/\" \/>\n<meta property=\"og:locale\" content=\"ko_KR\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"600V DC Circuit Breakers - KDM Steel\" \/>\n<meta property=\"og:description\" content=\"They are relatively larger in terms of physical size and can accommodate a DC of up to 600 voltage as opposed to 48v DC circuit breakers. They are commonly applied in large-scale commercial and industrial plants. Of course in applications whose potential voltage difference between the two poles does not exceed 600v. As such, this [&hellip;]\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.kdmsteel.com\/ko\/600v-dc-\ud68c\ub85c-\ucc28\ub2e8\uae30\/\" \/>\n<meta property=\"og:site_name\" content=\"KDM Steel\" \/>\n<meta property=\"article:published_time\" content=\"2024-02-23T03:47:47+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/www.kdmsteel.com\/wp-content\/uploads\/2024\/02\/Circuit-Breaker-Components-1.png\" \/>\n\t<meta property=\"og:image:width\" content=\"800\" \/>\n\t<meta property=\"og:image:height\" content=\"450\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/png\" \/>\n<meta name=\"author\" content=\"Kdmsteel Engineering Team\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"\uae00\uc4f4\uc774\" \/>\n\t<meta name=\"twitter:data1\" content=\"Kdmsteel Engineering Team\" \/>\n\t<meta name=\"twitter:label2\" content=\"\uc608\uc0c1 \ub418\ub294 \ud310\ub3c5 \uc2dc\uac04\" \/>\n\t<meta name=\"twitter:data2\" content=\"2\ubd84\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\\\/\\\/www.kdmsteel.com\\\/600v-dc-circuit-breakers\\\/#article\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.kdmsteel.com\\\/600v-dc-circuit-breakers\\\/\"},\"author\":{\"name\":\"Kdmsteel Engineering Team\",\"@id\":\"https:\\\/\\\/www.kdmsteel.com\\\/#\\\/schema\\\/person\\\/20f9dd106f5824b75813f83f5a192a5f\"},\"headline\":\"600V DC Circuit Breakers\",\"datePublished\":\"2024-02-23T03:47:47+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/www.kdmsteel.com\\\/600v-dc-circuit-breakers\\\/\"},\"wordCount\":150,\"commentCount\":0,\"publisher\":{\"@id\":\"https:\\\/\\\/www.kdmsteel.com\\\/#organization\"},\"image\":{\"@id\":\"https:\\\/\\\/www.kdmsteel.com\\\/600v-dc-circuit-breakers\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/www.kdmsteel.com\\\/wp-content\\\/uploads\\\/2024\\\/02\\\/Circuit-Breaker-Components-1.png\",\"articleSection\":[\"Blog\"],\"inLanguage\":\"ko-KR\",\"potentialAction\":[{\"@type\":\"CommentAction\",\"name\":\"Comment\",\"target\":[\"https:\\\/\\\/www.kdmsteel.com\\\/600v-dc-circuit-breakers\\\/#respond\"]}]},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/www.kdmsteel.com\\\/600v-dc-circuit-breakers\\\/\",\"url\":\"https:\\\/\\\/www.kdmsteel.com\\\/600v-dc-circuit-breakers\\\/\",\"name\":\"600V DC Circuit Breakers - KDM Steel\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.kdmsteel.com\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/www.kdmsteel.com\\\/600v-dc-circuit-breakers\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/www.kdmsteel.com\\\/600v-dc-circuit-breakers\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/www.kdmsteel.com\\\/wp-content\\\/uploads\\\/2024\\\/02\\\/Circuit-Breaker-Components-1.png\",\"datePublished\":\"2024-02-23T03:47:47+00:00\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/www.kdmsteel.com\\\/600v-dc-circuit-breakers\\\/#breadcrumb\"},\"inLanguage\":\"ko-KR\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/www.kdmsteel.com\\\/600v-dc-circuit-breakers\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"ko-KR\",\"@id\":\"https:\\\/\\\/www.kdmsteel.com\\\/600v-dc-circuit-breakers\\\/#primaryimage\",\"url\":\"https:\\\/\\\/www.kdmsteel.com\\\/wp-content\\\/uploads\\\/2024\\\/02\\\/Circuit-Breaker-Components-1.png\",\"contentUrl\":\"https:\\\/\\\/www.kdmsteel.com\\\/wp-content\\\/uploads\\\/2024\\\/02\\\/Circuit-Breaker-Components-1.png\",\"width\":800,\"height\":450,\"caption\":\"Circuit Breaker Components\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/www.kdmsteel.com\\\/600v-dc-circuit-breakers\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/www.kdmsteel.com\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"600V DC Circuit Breakers\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/www.kdmsteel.com\\\/#website\",\"url\":\"https:\\\/\\\/www.kdmsteel.com\\\/\",\"name\":\"KDM Steel\",\"description\":\"\",\"publisher\":{\"@id\":\"https:\\\/\\\/www.kdmsteel.com\\\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/www.kdmsteel.com\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"ko-KR\"},{\"@type\":\"Organization\",\"@id\":\"https:\\\/\\\/www.kdmsteel.com\\\/#organization\",\"name\":\"KDM Steel\",\"url\":\"https:\\\/\\\/www.kdmsteel.com\\\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"ko-KR\",\"@id\":\"https:\\\/\\\/www.kdmsteel.com\\\/#\\\/schema\\\/logo\\\/image\\\/\",\"url\":\"https:\\\/\\\/www.kdmsteel.com\\\/wp-content\\\/uploads\\\/2024\\\/05\\\/cropped-kdmsteel-logo.png\",\"contentUrl\":\"https:\\\/\\\/www.kdmsteel.com\\\/wp-content\\\/uploads\\\/2024\\\/05\\\/cropped-kdmsteel-logo.png\",\"width\":998,\"height\":535,\"caption\":\"KDM Steel\"},\"image\":{\"@id\":\"https:\\\/\\\/www.kdmsteel.com\\\/#\\\/schema\\\/logo\\\/image\\\/\"}},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/www.kdmsteel.com\\\/#\\\/schema\\\/person\\\/20f9dd106f5824b75813f83f5a192a5f\",\"name\":\"Kdmsteel Engineering Team\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"ko-KR\",\"@id\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/64b16d13078b1bec337dbb31f593dfd16bc530c88ca9fe9b1c9d2a002408080e?s=96&d=mm&r=g\",\"url\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/64b16d13078b1bec337dbb31f593dfd16bc530c88ca9fe9b1c9d2a002408080e?s=96&d=mm&r=g\",\"contentUrl\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/64b16d13078b1bec337dbb31f593dfd16bc530c88ca9fe9b1c9d2a002408080e?s=96&d=mm&r=g\",\"caption\":\"Kdmsteel Engineering Team\"}}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"600V DC \ud68c\ub85c \ucc28\ub2e8\uae30 - KDM Steel","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.kdmsteel.com\/ko\/600v-dc-\ud68c\ub85c-\ucc28\ub2e8\uae30\/","og_locale":"ko_KR","og_type":"article","og_title":"600V DC Circuit Breakers - KDM Steel","og_description":"They are relatively larger in terms of physical size and can accommodate a DC of up to 600 voltage as opposed to 48v DC circuit breakers. They are commonly applied in large-scale commercial and industrial plants. Of course in applications whose potential voltage difference between the two poles does not exceed 600v. As such, this [&hellip;]","og_url":"https:\/\/www.kdmsteel.com\/ko\/600v-dc-\ud68c\ub85c-\ucc28\ub2e8\uae30\/","og_site_name":"KDM Steel","article_published_time":"2024-02-23T03:47:47+00:00","og_image":[{"width":800,"height":450,"url":"https:\/\/www.kdmsteel.com\/wp-content\/uploads\/2024\/02\/Circuit-Breaker-Components-1.png","type":"image\/png"}],"author":"Kdmsteel Engineering Team","twitter_card":"summary_large_image","twitter_misc":{"\uae00\uc4f4\uc774":"Kdmsteel Engineering Team","\uc608\uc0c1 \ub418\ub294 \ud310\ub3c5 \uc2dc\uac04":"2\ubd84"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/www.kdmsteel.com\/600v-dc-circuit-breakers\/#article","isPartOf":{"@id":"https:\/\/www.kdmsteel.com\/600v-dc-circuit-breakers\/"},"author":{"name":"Kdmsteel Engineering Team","@id":"https:\/\/www.kdmsteel.com\/#\/schema\/person\/20f9dd106f5824b75813f83f5a192a5f"},"headline":"600V DC Circuit Breakers","datePublished":"2024-02-23T03:47:47+00:00","mainEntityOfPage":{"@id":"https:\/\/www.kdmsteel.com\/600v-dc-circuit-breakers\/"},"wordCount":150,"commentCount":0,"publisher":{"@id":"https:\/\/www.kdmsteel.com\/#organization"},"image":{"@id":"https:\/\/www.kdmsteel.com\/600v-dc-circuit-breakers\/#primaryimage"},"thumbnailUrl":"https:\/\/www.kdmsteel.com\/wp-content\/uploads\/2024\/02\/Circuit-Breaker-Components-1.png","articleSection":["Blog"],"inLanguage":"ko-KR","potentialAction":[{"@type":"CommentAction","name":"Comment","target":["https:\/\/www.kdmsteel.com\/600v-dc-circuit-breakers\/#respond"]}]},{"@type":"WebPage","@id":"https:\/\/www.kdmsteel.com\/600v-dc-circuit-breakers\/","url":"https:\/\/www.kdmsteel.com\/600v-dc-circuit-breakers\/","name":"600V DC \ud68c\ub85c \ucc28\ub2e8\uae30 - KDM Steel","isPartOf":{"@id":"https:\/\/www.kdmsteel.com\/#website"},"primaryImageOfPage":{"@id":"https:\/\/www.kdmsteel.com\/600v-dc-circuit-breakers\/#primaryimage"},"image":{"@id":"https:\/\/www.kdmsteel.com\/600v-dc-circuit-breakers\/#primaryimage"},"thumbnailUrl":"https:\/\/www.kdmsteel.com\/wp-content\/uploads\/2024\/02\/Circuit-Breaker-Components-1.png","datePublished":"2024-02-23T03:47:47+00:00","breadcrumb":{"@id":"https:\/\/www.kdmsteel.com\/600v-dc-circuit-breakers\/#breadcrumb"},"inLanguage":"ko-KR","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.kdmsteel.com\/600v-dc-circuit-breakers\/"]}]},{"@type":"ImageObject","inLanguage":"ko-KR","@id":"https:\/\/www.kdmsteel.com\/600v-dc-circuit-breakers\/#primaryimage","url":"https:\/\/www.kdmsteel.com\/wp-content\/uploads\/2024\/02\/Circuit-Breaker-Components-1.png","contentUrl":"https:\/\/www.kdmsteel.com\/wp-content\/uploads\/2024\/02\/Circuit-Breaker-Components-1.png","width":800,"height":450,"caption":"Circuit Breaker Components"},{"@type":"BreadcrumbList","@id":"https:\/\/www.kdmsteel.com\/600v-dc-circuit-breakers\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/www.kdmsteel.com\/"},{"@type":"ListItem","position":2,"name":"600V DC Circuit Breakers"}]},{"@type":"WebSite","@id":"https:\/\/www.kdmsteel.com\/#website","url":"https:\/\/www.kdmsteel.com\/","name":"KDM\uc2a4\ud2f8","description":"","publisher":{"@id":"https:\/\/www.kdmsteel.com\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/www.kdmsteel.com\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"ko-KR"},{"@type":"Organization","@id":"https:\/\/www.kdmsteel.com\/#organization","name":"KDM\uc2a4\ud2f8","url":"https:\/\/www.kdmsteel.com\/","logo":{"@type":"ImageObject","inLanguage":"ko-KR","@id":"https:\/\/www.kdmsteel.com\/#\/schema\/logo\/image\/","url":"https:\/\/www.kdmsteel.com\/wp-content\/uploads\/2024\/05\/cropped-kdmsteel-logo.png","contentUrl":"https:\/\/www.kdmsteel.com\/wp-content\/uploads\/2024\/05\/cropped-kdmsteel-logo.png","width":998,"height":535,"caption":"KDM Steel"},"image":{"@id":"https:\/\/www.kdmsteel.com\/#\/schema\/logo\/image\/"}},{"@type":"Person","@id":"https:\/\/www.kdmsteel.com\/#\/schema\/person\/20f9dd106f5824b75813f83f5a192a5f","name":"Kdmsteel \uc5d4\uc9c0\ub2c8\uc5b4\ub9c1 \ud300","image":{"@type":"ImageObject","inLanguage":"ko-KR","@id":"https:\/\/secure.gravatar.com\/avatar\/64b16d13078b1bec337dbb31f593dfd16bc530c88ca9fe9b1c9d2a002408080e?s=96&d=mm&r=g","url":"https:\/\/secure.gravatar.com\/avatar\/64b16d13078b1bec337dbb31f593dfd16bc530c88ca9fe9b1c9d2a002408080e?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/64b16d13078b1bec337dbb31f593dfd16bc530c88ca9fe9b1c9d2a002408080e?s=96&d=mm&r=g","caption":"Kdmsteel Engineering Team"}}]}},"_links":{"self":[{"href":"https:\/\/www.kdmsteel.com\/ko\/wp-json\/wp\/v2\/posts\/45227","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.kdmsteel.com\/ko\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.kdmsteel.com\/ko\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.kdmsteel.com\/ko\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.kdmsteel.com\/ko\/wp-json\/wp\/v2\/comments?post=45227"}],"version-history":[{"count":1,"href":"https:\/\/www.kdmsteel.com\/ko\/wp-json\/wp\/v2\/posts\/45227\/revisions"}],"predecessor-version":[{"id":45230,"href":"https:\/\/www.kdmsteel.com\/ko\/wp-json\/wp\/v2\/posts\/45227\/revisions\/45230"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.kdmsteel.com\/ko\/wp-json\/wp\/v2\/media\/45229"}],"wp:attachment":[{"href":"https:\/\/www.kdmsteel.com\/ko\/wp-json\/wp\/v2\/media?parent=45227"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.kdmsteel.com\/ko\/wp-json\/wp\/v2\/categories?post=45227"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.kdmsteel.com\/ko\/wp-json\/wp\/v2\/tags?post=45227"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}