{"id":34047,"date":"2021-09-23T02:07:03","date_gmt":"2021-09-23T02:07:03","guid":{"rendered":"http:\/\/www.kdmsteel.com\/?p=34047"},"modified":"2021-09-23T02:34:29","modified_gmt":"2021-09-23T02:34:29","slug":"how-to-ground-electrical-enclosure","status":"publish","type":"post","link":"https:\/\/www.kdmsteel.com\/id\/cara-membumikan-penutup-listrik\/","title":{"rendered":"Cara Membumikan Penutup Listrik: Panduan Lengkap"},"content":{"rendered":"<p>Pembumian penutup listrik yang tepat merupakan aspek vital untuk menyediakan keselamatan, kinerja, dan waktu aktif.<\/p>\n<p>Namun, selalu mudah untuk mengabaikannya <a href=\"https:\/\/en.wikipedia.org\/wiki\/Ground_(electricity)\">landasan<\/a> aspek, atau memperbaikinya secara tidak benar.<\/p>\n<p>Seringkali, <a href=\"https:\/\/www.kdmsteel.com\/id\/produsen-penutup-listrik-khusus\/\">kandang listrik<\/a> akan berfungsi seperti biasa dengan pentanahan yang salah, meskipun akan menimbulkan bahaya jika terjadi kesalahan.<\/p>\n<p>Panel kontrol umumnya mempunyai sumber daya input yang memiliki konduktor pentanahan yang pada akhirnya diikatkan ke penutup listrik.<\/p>\n<p>Panduan ini membahas beberapa praktik umum tentang cara membumikan penutup listrik:<\/p>\n<div id=\"ez-toc-container\" class=\"ez-toc-v2_0_82_2 counter-hierarchy ez-toc-counter ez-toc-grey ez-toc-container-direction\">\n<div class=\"ez-toc-title-container\">\n<p class=\"ez-toc-title\" style=\"cursor:inherit\">Daftar isi<\/p>\n<span class=\"ez-toc-title-toggle\"><a href=\"#\" class=\"ez-toc-pull-right ez-toc-btn ez-toc-btn-xs ez-toc-btn-default ez-toc-toggle\" aria-label=\"Beralih Daftar Isi\"><span class=\"ez-toc-js-icon-con\"><span class=\"\"><span class=\"eztoc-hide\" style=\"display:none;\">Beralih<\/span><span class=\"ez-toc-icon-toggle-span\"><svg style=\"fill: #999;color:#999\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\" class=\"list-377408\" width=\"20px\" height=\"20px\" viewbox=\"0 0 24 24\" fill=\"none\"><path d=\"M6 6H4v2h2V6zm14 0H8v2h12V6zM4 11h2v2H4v-2zm16 0H8v2h12v-2zM4 16h2v2H4v-2zm16 0H8v2h12v-2z\" fill=\"currentColor\"><\/path><\/svg><svg style=\"fill: #999;color:#999\" class=\"arrow-unsorted-368013\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\" width=\"10px\" height=\"10px\" viewbox=\"0 0 24 24\" version=\"1.2\" baseprofile=\"tiny\"><path d=\"M18.2 9.3l-6.2-6.3-6.2 6.3c-.2.2-.3.4-.3.7s.1.5.3.7c.2.2.4.3.7.3h11c.3 0 .5-.1.7-.3.2-.2.3-.5.3-.7s-.1-.5-.3-.7zM5.8 14.7l6.2 6.3 6.2-6.3c.2-.2.3-.5.3-.7s-.1-.5-.3-.7c-.2-.2-.4-.3-.7-.3h-11c-.3 0-.5.1-.7.3-.2.2-.3.5-.3.7s.1.5.3.7z\"\/><\/svg><\/span><\/span><\/span><\/a><\/span><\/div>\n<nav><ul class='ez-toc-list ez-toc-list-level-1' ><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-1\" href=\"https:\/\/www.kdmsteel.com\/id\/cara-membumikan-penutup-listrik\/#Earth_Grounding_Of_Electrical_Enclosure\" >Pembumian Bumi pada Penutup Listrik<\/a><ul class='ez-toc-list-level-3' ><li class='ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-2\" href=\"https:\/\/www.kdmsteel.com\/id\/cara-membumikan-penutup-listrik\/#Safety_First\" >Keselamatan adalah yang utama<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-3\" href=\"https:\/\/www.kdmsteel.com\/id\/cara-membumikan-penutup-listrik\/#Minimizing_Noise\" >Meminimalkan Kebisingan<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-4\" href=\"https:\/\/www.kdmsteel.com\/id\/cara-membumikan-penutup-listrik\/#Grounding_Hardware\" >Perangkat Keras Pembumian<\/a><\/li><\/ul><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-5\" href=\"https:\/\/www.kdmsteel.com\/id\/cara-membumikan-penutup-listrik\/#How_To_Ground_Enclosure_And_Backpanel\" >Cara Membumikan Penutup dan Panel Belakang<\/a><ul class='ez-toc-list-level-3' ><li class='ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-6\" href=\"https:\/\/www.kdmsteel.com\/id\/cara-membumikan-penutup-listrik\/#Grounding_Conductors\" >Konduktor Pembumian<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-7\" href=\"https:\/\/www.kdmsteel.com\/id\/cara-membumikan-penutup-listrik\/#Star_Grounding\" >Landasan Bintang<\/a><\/li><\/ul><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-8\" href=\"https:\/\/www.kdmsteel.com\/id\/cara-membumikan-penutup-listrik\/#Grounding_Power_Supplies_VFDs_PLCs_And_Other_Devices\" >Pembumian Catu Daya, VFD, PLC, dan Perangkat Lainnya<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-9\" href=\"https:\/\/www.kdmsteel.com\/id\/cara-membumikan-penutup-listrik\/#Chassis_Ground_And_Isolated_Ground\" >Grounding Sasis dan Grounding Terisolasi<\/a><\/li><\/ul><\/nav><\/div>\n<h2><span class=\"ez-toc-section\" id=\"Earth_Grounding_Of_Electrical_Enclosure\"><\/span>Pembumian Bumi pada Penutup Listrik<span class=\"ez-toc-section-end\"><\/span><\/h2>\n<div class=\"ast-oembed-container\" style=\"height: 100%;\"><iframe loading=\"lazy\" title=\"Kandang listrik KDM IP65\" width=\"500\" height=\"281\" src=\"https:\/\/www.youtube.com\/embed\/JPp49Z308RI?feature=oembed\" frameborder=\"0\" allow=\"accelerometer; autoplay; clipboard-write; encrypted-media; gyroscope; picture-in-picture; web-share\" referrerpolicy=\"strict-origin-when-cross-origin\" allowfullscreen><\/iframe><\/div>\n<p>Pentanahan bumi mungkin bukan aktivitas yang akan Anda tangani secara langsung jika merancang perangkat elektronik. Akan tetapi, tetap penting untuk memahami dasar-dasar cara melakukannya.<\/p>\n<p>Hal ini dikarenakan hal tersebut merupakan bagian dari praktik terbaik yang diakui untuk merancang sistem kelistrikan yang aman.<\/p>\n<p>Secara khusus, Anda akan mempelajari sistem ikatan bumi untuk menentukan bagaimana sebuah gawai berasosiasi dengan sumber daya listrik besar.<\/p>\n<p>Mayoritas sistem tenaga listrik komersial dan perumahan dilengkapi batang pentanahan.<\/p>\n<p>Batang pentanahan bumi merupakan batang logam yang sangat konduktif, yang dibenamkan ke dalam beton dan memberikan jalur aman untuk arus liar.<\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"size-full wp-image-34048 aligncenter\" src=\"http:\/\/www.kdmsteel.com\/wp-content\/uploads\/2021\/09\/Figure-1-Grounded-Electrical-Enclosure-scaled.jpg\" alt=\"Penutup Listrik yang Dibumikan\" width=\"2560\" height=\"1919\" srcset=\"https:\/\/www.kdmsteel.com\/wp-content\/uploads\/2021\/09\/Figure-1-Grounded-Electrical-Enclosure-scaled.jpg 2560w, https:\/\/www.kdmsteel.com\/wp-content\/uploads\/2021\/09\/Figure-1-Grounded-Electrical-Enclosure-150x112.jpg 150w, https:\/\/www.kdmsteel.com\/wp-content\/uploads\/2021\/09\/Figure-1-Grounded-Electrical-Enclosure-768x576.jpg 768w, https:\/\/www.kdmsteel.com\/wp-content\/uploads\/2021\/09\/Figure-1-Grounded-Electrical-Enclosure-1536x1151.jpg 1536w, https:\/\/www.kdmsteel.com\/wp-content\/uploads\/2021\/09\/Figure-1-Grounded-Electrical-Enclosure-2048x1535.jpg 2048w\" sizes=\"auto, (max-width: 2560px) 100vw, 2560px\" \/><\/p>\n<p style=\"text-align: center;\">Penutup Listrik yang Dibumikan<\/p>\n<p>Komponen sistem kelistrikan dihubungkan ke tanah melalui batang pentanahan di dalam penutup listrik.<\/p>\n<p>Jika terjadi kesalahan kelistrikan, seperti gangguan tanah atau hubungan arus pendek, tanah berfungsi sebagai fitur pengaman yang melindungi dari bahaya terkait.<\/p>\n<p>Meski demikian, tujuan pentanahan bumi tidak hanya untuk mengalirkan arus liar ke dalam tanah.<\/p>\n<p>Hal ini berlaku untuk mengembalikan daya ke sumbernya, di mana lonjakan arus akan memicu alat arus berlebih seperti pemutus arus.<\/p>\n<p>Pemutus arus ini kemudian aktif dan menghentikan aliran arus.<\/p>\n<h3><span class=\"ez-toc-section\" id=\"Safety_First\"><\/span>Keselamatan adalah yang utama<span class=\"ez-toc-section-end\"><\/span><\/h3>\n<p>Dari sudut pandang keselamatan, penutup listrik harus diarde secara positif dan benar agar terhindar dari kesalahan kelistrikan.<\/p>\n<p>Resistensi jalur ground dari kotak penutup listrik kembali ke ground sumber harus sangat rendah.<\/p>\n<p>Hal ini memastikan bahwa ketika konduktor berenergi menyentuh <a href=\"https:\/\/www.kdmsteel.com\/id\/kandang-listrik-khusus-2\/\">lampiran<\/a>, arus gangguan konsekuensial mendapat jalur impedansi rendah untuk disalurkan dengan aman ke tanah.<\/p>\n<p>Hal ini memungkinkan bagian yang memiliki arus lebih untuk membuka dan memutus arus sirkuit secara positif dan cepat guna memutus sumber daya.<\/p>\n<p>Penutup listrik yang tidak dibumikan atau tidak dibumikan dengan benar tidak akan mengatasi kesalahan dengan cepat, jika memang terjadi.<\/p>\n<p>Oleh karena itu, ia dapat tetap beroperasi dan diberi energi, yang kemungkinan membuat penutup listrik memiliki tegangan yang bukan nol.<\/p>\n<p>Orang yang bekerja di sekitar atau di dalam kotak penutup ini mungkin akan tersengat listrik akibat tegangan mengambang.<\/p>\n<h3><span class=\"ez-toc-section\" id=\"Minimizing_Noise\"><\/span>Meminimalkan Kebisingan<span class=\"ez-toc-section-end\"><\/span><\/h3>\n<p>Praktik pentanahan penutup listrik yang baik akan membantu meredam kebisingan listrik apa pun, seperti yang dihasilkan oleh <a href=\"https:\/\/en.wikipedia.org\/wiki\/Variable-frequency_drive\">penggerak frekuensi variabel<\/a> (VFD).<\/p>\n<p>Kebisingan yang rendah menghasilkan berkurangnya kemungkinan timbulnya masalah pada peralatan sensitif.<\/p>\n<h3><span class=\"ez-toc-section\" id=\"Grounding_Hardware\"><\/span>Perangkat Keras Pembumian<span class=\"ez-toc-section-end\"><\/span><\/h3>\n<p>Anda harus mencantumkan semua perangkat keras konektor listrik yang digunakan dalam pentanahan penutup panel kontrol. Beberapa cara terminasi yang umum untuk kabel pentanahan meliputi:<\/p>\n<ul>\n<li><strong>Lug Pembumian:\u00a0<\/strong>Fitting ini memiliki bagian kompresi yang menerima kabel masuk. Terdapat lubang yang memungkinkan Anda untuk memasangnya pada panel belakang atau stud penutup yang sesuai.<\/li>\n<li><strong>Batang Pembumian:\u00a0<\/strong>Ini merujuk pada batang yang dapat menghubungkan banyak konduktor arde, dan biasanya dipasang pada panel belakang.<\/li>\n<li><strong>Terminal Pembumian: <\/strong>Blok terminal kompresi, umumnya berwarna hijau\/kuning atau hijau, yang terhubung ke rel DIN jika dipasang atau panel belakang.<\/li>\n<\/ul>\n<h2><span class=\"ez-toc-section\" id=\"How_To_Ground_Enclosure_And_Backpanel\"><\/span>Cara Membumikan Penutup dan Panel Belakang<span class=\"ez-toc-section-end\"><\/span><\/h2>\n<p>Penutup panel kontrol biasanya terbuat dari logam dan memiliki panel belakang logam interior yang digunakan untuk memasang komponen.<\/p>\n<p>Bahkan penutup listrik non-logam biasanya terdiri dari panel belakang logam.<\/p>\n<p>Penutup listrik yang terdaftar di UL akan disertai dengan dokumen relevan, yang harus Anda ikuti selama pemasangan.<\/p>\n<p>Selain itu, ini akan mencakup perangkat keras yang akan Anda gunakan untuk membumikan semua komponen logam pada lemari penutup.<\/p>\n<p>Perangkat keras mungkin terdiri dari stiker tanda arde yang berbeda, yang perlu Anda tempatkan di setiap titik sambungan.<\/p>\n<p>Seringkali, Anda mendaratkan ground yang masuk ke terminal grounding, batang, atau lug yang terpasang di panel belakang.<\/p>\n<p>Konektor ini menghubungkan konduktor ground ke panel belakang penutup.<\/p>\n<p>Panel belakang biasanya dipasang menggunakan sekrup mesin atau mur dan ring bintang untuk memastikannya terpasang pada penutup listrik logam.<\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"size-full wp-image-34049 aligncenter\" src=\"http:\/\/www.kdmsteel.com\/wp-content\/uploads\/2021\/09\/Figure-2-Electrical-Enclosure-Grounding.jpg\" alt=\"Pembumian Kandang Listrik\" width=\"1350\" height=\"900\" srcset=\"https:\/\/www.kdmsteel.com\/wp-content\/uploads\/2021\/09\/Figure-2-Electrical-Enclosure-Grounding.jpg 1350w, https:\/\/www.kdmsteel.com\/wp-content\/uploads\/2021\/09\/Figure-2-Electrical-Enclosure-Grounding-150x100.jpg 150w, https:\/\/www.kdmsteel.com\/wp-content\/uploads\/2021\/09\/Figure-2-Electrical-Enclosure-Grounding-768x512.jpg 768w\" sizes=\"auto, (max-width: 1350px) 100vw, 1350px\" \/><\/p>\n<p style=\"text-align: center;\">Pembumian Kandang Listrik<\/p>\n<p>Pintu logam, baik jenis engselnya bisa dilepas atau tipe engsel kontinu, memerlukan jumper pengikat independen dari panel belakang atau penutup ke pintu.<\/p>\n<p>Biasanya, pintu dilengkapi dengan kancing untuk fungsi ini.<\/p>\n<p>Selalu disarankan agar sambungan pembumian penutup listrik yang dilakukan pada bagian luar yang dicat, catnya dikikis hingga ke bagian logam polos.<\/p>\n<p>Ini lebih disukai bahkan jika Anda menggunakan ring bintang untuk memastikan sambungan terbaik.<\/p>\n<p>Lebih jauh lagi, ketika Anda memasang rel DIN pada panel belakang, Anda perlu menggunakan sekrup mesin yang disadap dan dibor untuk membuat sambungan yang terikat.<\/p>\n<h3><span class=\"ez-toc-section\" id=\"Grounding_Conductors\"><\/span>Konduktor Pembumian<span class=\"ez-toc-section-end\"><\/span><\/h3>\n<p>Anda harus menentukan ukuran konduktor pentanahan sesuai dengan standar industri yang relevan, tergantung pada ukuran perangkat arus lebih yang melindungi sirkuit.<\/p>\n<p>Warna konduktor pentanahan yang diisolasi adalah hijau atau hijau dengan garis kuning, menurut NFPA 79.<\/p>\n<p>Meskipun demikian, ada beberapa kasus di mana tali kepang atau konduktor polos dapat diterima, seperti saat fleksibilitas dibutuhkan. Anda dapat mengidentifikasi titik pentanahan dengan istilah potensial bumi (PE) atau simbol.<\/p>\n<h3><span class=\"ez-toc-section\" id=\"Star_Grounding\"><\/span>Landasan Bintang<span class=\"ez-toc-section-end\"><\/span><\/h3>\n<p>Anda tidak boleh melakukan penyambungan pentanahan penutup listrik dengan cara \u201cdaisy-chaining\u201d atau jumper berurutan.<\/p>\n<p>Hal ini disebabkan oleh fakta bahwa setiap interkoneksi yang gagal akan memutuskan kopling ground dari semua perangkat berikutnya.<\/p>\n<p>Sebaliknya, Anda harus menggunakan desain \u201cbintang\u201d di mana setiap ground memiliki kopling home-run ke bar grounding primer.<\/p>\n<h2><span class=\"ez-toc-section\" id=\"Grounding_Power_Supplies_VFDs_PLCs_And_Other_Devices\"><\/span>Pembumian Catu Daya, VFD, PLC, dan Perangkat Lainnya<span class=\"ez-toc-section-end\"><\/span><\/h2>\n<p>Perangkat umum yang dipasang dalam wadah listrik biasanya mempunyai persyaratan pentanahan khusus.<\/p>\n<p>Oleh karena itu, Anda harus hati-hati mengikuti panduan instalasi untuk catu daya, penggerak frekuensi variabel, PLC, dan perangkat lainnya.<\/p>\n<p>Hal ini karena kadang kala spesifikasi pentanahan lebih ketat, seperti membutuhkan konduktor berukuran besar dibandingkan yang seharusnya diperlukan.<\/p>\n<h2><span class=\"ez-toc-section\" id=\"Chassis_Ground_And_Isolated_Ground\"><\/span>Grounding Sasis dan Grounding Terisolasi<span class=\"ez-toc-section-end\"><\/span><\/h2>\n<p>Kadang-kadang istilah &quot;ground chassis&quot; digunakan untuk mendefinisikan penutup listrik yang diarde. Kadang-kadang, produsen merekomendasikan &quot;ground terisolasi&quot;.<\/p>\n<p>Meski demikian, mayoritas penutup listrik tidak perlu dilengkapi dengan sistem pentanahan independen yang tetap.<\/p>\n<p>Sistem pentanahan bintang yang dipasang dengan benar menawarkan pemasangan penutup panel kontrol listrik yang aman dan dapat diandalkan.<\/p>\n<p>Namun, Anda dapat menggunakan komponen penutup listrik ground to ground pada sasis. Teknik ini memerlukan perancangan satu lokasi pentanahan untuk seluruh komponen penutup.<\/p>\n<p>Karena sejumlah alasan, akan bermanfaat jika semua arus listrik Anda mengalir melalui satu titik.<\/p>\n<p>Di antara alasan paling penting untuk menggunakan ground chassis adalah kenyataan bahwa ia berfungsi sebagai mekanisme distribusi daya untuk penutup listrik Anda.<\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"size-full wp-image-34050 aligncenter\" src=\"http:\/\/www.kdmsteel.com\/wp-content\/uploads\/2021\/09\/Figure-3-Chassis-Grounding-of-Electrical-Enclosure.jpg\" alt=\"Pembumian Sasis Kandang Listrik\" width=\"500\" height=\"333\" srcset=\"https:\/\/www.kdmsteel.com\/wp-content\/uploads\/2021\/09\/Figure-3-Chassis-Grounding-of-Electrical-Enclosure.jpg 500w, https:\/\/www.kdmsteel.com\/wp-content\/uploads\/2021\/09\/Figure-3-Chassis-Grounding-of-Electrical-Enclosure-150x100.jpg 150w\" sizes=\"auto, (max-width: 500px) 100vw, 500px\" \/><\/p>\n<p style=\"text-align: center;\">Pembumian Sasis Kandang Listrik<\/p>\n<p>Jenis ground ini dapat dengan mudah diamati pada truk atau mobil. Kendaraan menggunakan ground sasis sebagai sarana untuk mengalirkan arus listrik ke semua bagian yang membutuhkannya.<\/p>\n<p>Starter kendaraan, radio, AC, dan komponen lainnya semuanya memiliki arus yang mengalir melalui ground sasis.<\/p>\n<p>Mekanisme pentanahan sering kali terdapat pada rangka atau bagian logam lain pada rangka kendaraan.<\/p>\n<p>Mayoritas ground sasis disambungkan hanya pada satu lokasi untuk mencegah \u201cground loop\u201d yang dapat menyebabkan interferensi.<\/p>\n<p>Ini membuatnya penting untuk memastikan perangkat listrik Anda memiliki sasis yang konduktif.<\/p>\n<p>Itulah alasan mengapa penutup alumunium dan baja menjadi pilihan terbaik untuk berbagai jenis peralatan elektronik.<\/p>\n<p>Mereka menawarkan cara yang sederhana dan sangat konduktif untuk membumikan dan mengikat peralatan elektronik.<\/p>\n<p>Untuk pertanyaan atau pertanyaan apa pun tentang penutup listrik, KDMSteel siap membantu \u2013 <a href=\"https:\/\/www.kdmsteel.com\/id\/kontak\/\">Hubungi kami sekarang<\/a>.<\/p>","protected":false},"excerpt":{"rendered":"<p>Proper electrical enclosure grounding is a vital facet for providing safety, performance and uptime. However, it is always easy to overlook grounding aspects, or to fix them incorrectly. Often, the electrical enclosure will perform as usual with incorrect grounding, though will result in a danger if a fault happens. Control panels typically feature an input [&hellip;]<\/p>\n","protected":false},"author":2,"featured_media":0,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"site-sidebar-layout":"default","site-content-layout":"default","ast-site-content-layout":"default","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","ast-disable-related-posts":"","theme-transparent-header-meta":"default","adv-header-id-meta":"","stick-header-meta":"default","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"default","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"footnotes":""},"categories":[1],"tags":[],"class_list":["post-34047","post","type-post","status-publish","format-standard","hentry","category-blog"],"acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v27.4 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>How To Ground Electrical Enclosure: The Complete Guide - KDM Steel<\/title>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.kdmsteel.com\/id\/cara-membumikan-penutup-listrik\/\" \/>\n<meta property=\"og:locale\" content=\"id_ID\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"How To Ground Electrical Enclosure: The Complete Guide - KDM Steel\" \/>\n<meta property=\"og:description\" content=\"Proper electrical enclosure grounding is a vital facet for providing safety, performance and uptime. However, it is always easy to overlook grounding aspects, or to fix them incorrectly. Often, the electrical enclosure will perform as usual with incorrect grounding, though will result in a danger if a fault happens. Control panels typically feature an input [&hellip;]\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.kdmsteel.com\/id\/cara-membumikan-penutup-listrik\/\" \/>\n<meta property=\"og:site_name\" content=\"KDM Steel\" \/>\n<meta property=\"article:published_time\" content=\"2021-09-23T02:07:03+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2021-09-23T02:34:29+00:00\" \/>\n<meta property=\"og:image\" content=\"http:\/\/www.kdmsteel.com\/wp-content\/uploads\/2021\/09\/Figure-1-Grounded-Electrical-Enclosure-scaled.jpg\" \/>\n<meta name=\"author\" content=\"Sunny\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Ditulis oleh\" \/>\n\t<meta name=\"twitter:data1\" content=\"Sunny\" \/>\n\t<meta name=\"twitter:label2\" content=\"Estimasi waktu membaca\" \/>\n\t<meta name=\"twitter:data2\" content=\"6 menit\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\\\/\\\/www.kdmsteel.com\\\/how-to-ground-electrical-enclosure\\\/#article\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.kdmsteel.com\\\/how-to-ground-electrical-enclosure\\\/\"},\"author\":{\"name\":\"Sunny\",\"@id\":\"https:\\\/\\\/www.kdmsteel.com\\\/#\\\/schema\\\/person\\\/0392524df5bea29020d93c4d283f1fc0\"},\"headline\":\"How To Ground Electrical Enclosure: The Complete Guide\",\"datePublished\":\"2021-09-23T02:07:03+00:00\",\"dateModified\":\"2021-09-23T02:34:29+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/www.kdmsteel.com\\\/how-to-ground-electrical-enclosure\\\/\"},\"wordCount\":1245,\"commentCount\":0,\"publisher\":{\"@id\":\"https:\\\/\\\/www.kdmsteel.com\\\/#organization\"},\"image\":{\"@id\":\"https:\\\/\\\/www.kdmsteel.com\\\/how-to-ground-electrical-enclosure\\\/#primaryimage\"},\"thumbnailUrl\":\"http:\\\/\\\/www.kdmsteel.com\\\/wp-content\\\/uploads\\\/2021\\\/09\\\/Figure-1-Grounded-Electrical-Enclosure-scaled.jpg\",\"articleSection\":[\"Blog\"],\"inLanguage\":\"id\",\"potentialAction\":[{\"@type\":\"CommentAction\",\"name\":\"Comment\",\"target\":[\"https:\\\/\\\/www.kdmsteel.com\\\/how-to-ground-electrical-enclosure\\\/#respond\"]}]},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/www.kdmsteel.com\\\/how-to-ground-electrical-enclosure\\\/\",\"url\":\"https:\\\/\\\/www.kdmsteel.com\\\/how-to-ground-electrical-enclosure\\\/\",\"name\":\"How To Ground Electrical Enclosure: The Complete Guide - KDM Steel\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.kdmsteel.com\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/www.kdmsteel.com\\\/how-to-ground-electrical-enclosure\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/www.kdmsteel.com\\\/how-to-ground-electrical-enclosure\\\/#primaryimage\"},\"thumbnailUrl\":\"http:\\\/\\\/www.kdmsteel.com\\\/wp-content\\\/uploads\\\/2021\\\/09\\\/Figure-1-Grounded-Electrical-Enclosure-scaled.jpg\",\"datePublished\":\"2021-09-23T02:07:03+00:00\",\"dateModified\":\"2021-09-23T02:34:29+00:00\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/www.kdmsteel.com\\\/how-to-ground-electrical-enclosure\\\/#breadcrumb\"},\"inLanguage\":\"id\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/www.kdmsteel.com\\\/how-to-ground-electrical-enclosure\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"id\",\"@id\":\"https:\\\/\\\/www.kdmsteel.com\\\/how-to-ground-electrical-enclosure\\\/#primaryimage\",\"url\":\"http:\\\/\\\/www.kdmsteel.com\\\/wp-content\\\/uploads\\\/2021\\\/09\\\/Figure-1-Grounded-Electrical-Enclosure-scaled.jpg\",\"contentUrl\":\"http:\\\/\\\/www.kdmsteel.com\\\/wp-content\\\/uploads\\\/2021\\\/09\\\/Figure-1-Grounded-Electrical-Enclosure-scaled.jpg\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/www.kdmsteel.com\\\/how-to-ground-electrical-enclosure\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/www.kdmsteel.com\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"How To Ground Electrical Enclosure: The Complete Guide\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/www.kdmsteel.com\\\/#website\",\"url\":\"https:\\\/\\\/www.kdmsteel.com\\\/\",\"name\":\"KDM Steel\",\"description\":\"\",\"publisher\":{\"@id\":\"https:\\\/\\\/www.kdmsteel.com\\\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/www.kdmsteel.com\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"id\"},{\"@type\":\"Organization\",\"@id\":\"https:\\\/\\\/www.kdmsteel.com\\\/#organization\",\"name\":\"KDM Steel\",\"url\":\"https:\\\/\\\/www.kdmsteel.com\\\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"id\",\"@id\":\"https:\\\/\\\/www.kdmsteel.com\\\/#\\\/schema\\\/logo\\\/image\\\/\",\"url\":\"https:\\\/\\\/www.kdmsteel.com\\\/wp-content\\\/uploads\\\/2024\\\/05\\\/cropped-kdmsteel-logo.png\",\"contentUrl\":\"https:\\\/\\\/www.kdmsteel.com\\\/wp-content\\\/uploads\\\/2024\\\/05\\\/cropped-kdmsteel-logo.png\",\"width\":998,\"height\":535,\"caption\":\"KDM Steel\"},\"image\":{\"@id\":\"https:\\\/\\\/www.kdmsteel.com\\\/#\\\/schema\\\/logo\\\/image\\\/\"}},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/www.kdmsteel.com\\\/#\\\/schema\\\/person\\\/0392524df5bea29020d93c4d283f1fc0\",\"name\":\"Sunny\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"id\",\"@id\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/992fa667b6993ee8a51eda68091f8767697dfd9f8ac786a86f4adbb19c0a9bac?s=96&d=mm&r=g\",\"url\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/992fa667b6993ee8a51eda68091f8767697dfd9f8ac786a86f4adbb19c0a9bac?s=96&d=mm&r=g\",\"contentUrl\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/992fa667b6993ee8a51eda68091f8767697dfd9f8ac786a86f4adbb19c0a9bac?s=96&d=mm&r=g\",\"caption\":\"Sunny\"}}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"Cara Membumikan Penutup Listrik: Panduan Lengkap - KDM Steel","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.kdmsteel.com\/id\/cara-membumikan-penutup-listrik\/","og_locale":"id_ID","og_type":"article","og_title":"How To Ground Electrical Enclosure: The Complete Guide - KDM Steel","og_description":"Proper electrical enclosure grounding is a vital facet for providing safety, performance and uptime. However, it is always easy to overlook grounding aspects, or to fix them incorrectly. Often, the electrical enclosure will perform as usual with incorrect grounding, though will result in a danger if a fault happens. Control panels typically feature an input [&hellip;]","og_url":"https:\/\/www.kdmsteel.com\/id\/cara-membumikan-penutup-listrik\/","og_site_name":"KDM Steel","article_published_time":"2021-09-23T02:07:03+00:00","article_modified_time":"2021-09-23T02:34:29+00:00","og_image":[{"url":"http:\/\/www.kdmsteel.com\/wp-content\/uploads\/2021\/09\/Figure-1-Grounded-Electrical-Enclosure-scaled.jpg","type":"","width":"","height":""}],"author":"Sunny","twitter_card":"summary_large_image","twitter_misc":{"Ditulis oleh":"Sunny","Estimasi waktu membaca":"6 menit"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/www.kdmsteel.com\/how-to-ground-electrical-enclosure\/#article","isPartOf":{"@id":"https:\/\/www.kdmsteel.com\/how-to-ground-electrical-enclosure\/"},"author":{"name":"Sunny","@id":"https:\/\/www.kdmsteel.com\/#\/schema\/person\/0392524df5bea29020d93c4d283f1fc0"},"headline":"How To Ground Electrical Enclosure: The Complete Guide","datePublished":"2021-09-23T02:07:03+00:00","dateModified":"2021-09-23T02:34:29+00:00","mainEntityOfPage":{"@id":"https:\/\/www.kdmsteel.com\/how-to-ground-electrical-enclosure\/"},"wordCount":1245,"commentCount":0,"publisher":{"@id":"https:\/\/www.kdmsteel.com\/#organization"},"image":{"@id":"https:\/\/www.kdmsteel.com\/how-to-ground-electrical-enclosure\/#primaryimage"},"thumbnailUrl":"http:\/\/www.kdmsteel.com\/wp-content\/uploads\/2021\/09\/Figure-1-Grounded-Electrical-Enclosure-scaled.jpg","articleSection":["Blog"],"inLanguage":"id","potentialAction":[{"@type":"CommentAction","name":"Comment","target":["https:\/\/www.kdmsteel.com\/how-to-ground-electrical-enclosure\/#respond"]}]},{"@type":"WebPage","@id":"https:\/\/www.kdmsteel.com\/how-to-ground-electrical-enclosure\/","url":"https:\/\/www.kdmsteel.com\/how-to-ground-electrical-enclosure\/","name":"Cara Membumikan Penutup Listrik: Panduan Lengkap - KDM Steel","isPartOf":{"@id":"https:\/\/www.kdmsteel.com\/#website"},"primaryImageOfPage":{"@id":"https:\/\/www.kdmsteel.com\/how-to-ground-electrical-enclosure\/#primaryimage"},"image":{"@id":"https:\/\/www.kdmsteel.com\/how-to-ground-electrical-enclosure\/#primaryimage"},"thumbnailUrl":"http:\/\/www.kdmsteel.com\/wp-content\/uploads\/2021\/09\/Figure-1-Grounded-Electrical-Enclosure-scaled.jpg","datePublished":"2021-09-23T02:07:03+00:00","dateModified":"2021-09-23T02:34:29+00:00","breadcrumb":{"@id":"https:\/\/www.kdmsteel.com\/how-to-ground-electrical-enclosure\/#breadcrumb"},"inLanguage":"id","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.kdmsteel.com\/how-to-ground-electrical-enclosure\/"]}]},{"@type":"ImageObject","inLanguage":"id","@id":"https:\/\/www.kdmsteel.com\/how-to-ground-electrical-enclosure\/#primaryimage","url":"http:\/\/www.kdmsteel.com\/wp-content\/uploads\/2021\/09\/Figure-1-Grounded-Electrical-Enclosure-scaled.jpg","contentUrl":"http:\/\/www.kdmsteel.com\/wp-content\/uploads\/2021\/09\/Figure-1-Grounded-Electrical-Enclosure-scaled.jpg"},{"@type":"BreadcrumbList","@id":"https:\/\/www.kdmsteel.com\/how-to-ground-electrical-enclosure\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/www.kdmsteel.com\/"},{"@type":"ListItem","position":2,"name":"How To Ground Electrical Enclosure: The Complete Guide"}]},{"@type":"WebSite","@id":"https:\/\/www.kdmsteel.com\/#website","url":"https:\/\/www.kdmsteel.com\/","name":"Baja KDM","description":"","publisher":{"@id":"https:\/\/www.kdmsteel.com\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/www.kdmsteel.com\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"id"},{"@type":"Organization","@id":"https:\/\/www.kdmsteel.com\/#organization","name":"Baja KDM","url":"https:\/\/www.kdmsteel.com\/","logo":{"@type":"ImageObject","inLanguage":"id","@id":"https:\/\/www.kdmsteel.com\/#\/schema\/logo\/image\/","url":"https:\/\/www.kdmsteel.com\/wp-content\/uploads\/2024\/05\/cropped-kdmsteel-logo.png","contentUrl":"https:\/\/www.kdmsteel.com\/wp-content\/uploads\/2024\/05\/cropped-kdmsteel-logo.png","width":998,"height":535,"caption":"KDM Steel"},"image":{"@id":"https:\/\/www.kdmsteel.com\/#\/schema\/logo\/image\/"}},{"@type":"Person","@id":"https:\/\/www.kdmsteel.com\/#\/schema\/person\/0392524df5bea29020d93c4d283f1fc0","name":"Cerah","image":{"@type":"ImageObject","inLanguage":"id","@id":"https:\/\/secure.gravatar.com\/avatar\/992fa667b6993ee8a51eda68091f8767697dfd9f8ac786a86f4adbb19c0a9bac?s=96&d=mm&r=g","url":"https:\/\/secure.gravatar.com\/avatar\/992fa667b6993ee8a51eda68091f8767697dfd9f8ac786a86f4adbb19c0a9bac?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/992fa667b6993ee8a51eda68091f8767697dfd9f8ac786a86f4adbb19c0a9bac?s=96&d=mm&r=g","caption":"Sunny"}}]}},"_links":{"self":[{"href":"https:\/\/www.kdmsteel.com\/id\/wp-json\/wp\/v2\/posts\/34047","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.kdmsteel.com\/id\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.kdmsteel.com\/id\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.kdmsteel.com\/id\/wp-json\/wp\/v2\/users\/2"}],"replies":[{"embeddable":true,"href":"https:\/\/www.kdmsteel.com\/id\/wp-json\/wp\/v2\/comments?post=34047"}],"version-history":[{"count":0,"href":"https:\/\/www.kdmsteel.com\/id\/wp-json\/wp\/v2\/posts\/34047\/revisions"}],"wp:attachment":[{"href":"https:\/\/www.kdmsteel.com\/id\/wp-json\/wp\/v2\/media?parent=34047"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.kdmsteel.com\/id\/wp-json\/wp\/v2\/categories?post=34047"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.kdmsteel.com\/id\/wp-json\/wp\/v2\/tags?post=34047"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}